Specifications - LG DLEY1701VE Owner's Manual

Hide thumbs Also See for DLEY1701VE:
Table of Contents

Advertisement

Available languages

Available languages

TROUBLESHOOTING
/ SPECWICAiTIONS
51
Before
Calling
for
Service
(conf.)
Prololem
Possible Causes
Solutions
There are no
• The function
of this cycle is to
• Use an iron to make creases.
creases left on
remove wrinkles from fabric.
garment
after
Steam Fresh
TM
Odors remain
, Steam Fresh
TM
did not remove
• Fabrics containing
strong odors should be washed in a
in clothing after
odor completely,
normal cycle.
Steam Fresh
TM
• Install a shorter or straighter
duct run. See the Installation
Instructions.
Flow Sense
TM
indicator
shows four
bars during
the
drying cycle
The display
shows
"d go',
"d95"
, Ductwork
is too long or has too
many turns/restrictions.
, Significant
blockage of the
ductwork
clue to lint buildup
or
debris.
,The appliance
has detected
a
restriction
in the external
dryer
venting.
• The duct work is about 90%-95%
blocked.
("dg0" or"d95"
error code
displayed
2 hours only)
• House exhaust system blocked.
• Ductwork
should be checked/cleaned
soon.
Dryer can be used in this condition,
but drying times may
be longer.
• If exhaust restrictions
are sensed bythe
Flow Sense
TM
system, the indicator
will remain on for two hours after
the end of the cycle. Opening
the door or pressing the
POWER button
will turn offthe
display.
• Do not use the dryer until the exhaust system has been
cleaned and/or repaired.
Using the dryer with a severely
restricted
exhaust is dangerous
and could result in a fire
or other property
damage.
• Check the outside dryer vent while the dryer is operating
to make sure there is strong airflow.
, If the exhaust system is extremely
long, have it repaired or
rerouted.
• Keep the area around the dryer clean and free of clutter.
• Check vent hood for damage or lint clogging.
• Make sure the area around
the vent hood is clear.
SPECIFICATIONS
SteamDrver,_
Models
DLEY1701_E
DLGY1702_E
Description
Steam Dryer
Electrical requirements
Please refer to the rating label regarding
detailed information.
Gas requirements
NG 4-10.5 inches WC
LP: 8-13 inches WC (Gas Models only)
Max. water pressure
21.8 - 116 psi (150 - 800 kPa)
Dimensions
27" (W) X 28 15/16" (D) X 40 3/16" (H), 50 1/4" (D with door open)
68.6 cm (W) X 73.4 cm (D) X 102 cm (H), 127.5 cm (D with door open)
Net weight
Gas dryer : 137.6 Ibs (62.4 kg)
Electric dryer : 134.5 Ibs (61.0 kg)
Drying capacity
- Normal cycle
IEC 7.3 cu.ft. (22.5 Ib/10.2 kg)