LG DLEY1701VE Owner's Manual page 33

Hide thumbs Also See for DLEY1701VE:
Table of Contents

Advertisement

Available languages

Available languages

INSTALLAiTION
INSTRUCTIONS
33
Insfallafion
Tesf
(Ducf
check)
Once you have completed
the installation
of the dryer,
use this test to make sure the condition
of the exhaust
system is adequate for proper operation
of the dryer.
This test should be performed
to alert you to any serious
problems
in the exhaust system of your home.
• Your dryer features Flow Sense% an innovative
sensing
system that automatically
detects blockages and
restrictions
in dryer ductwork.
Keeping ductwork
clean
of lint buildup
and free of restrictions
allows clothes to
dry faster and reduces energy use.
- _
NOTE
The dryer should be cool before starting
this test. If
the dryer was warmed
up during
installation,
run the
AIR DRY cycle for a few minutes to reduce the interior
temperature.
To activate
the installation
test:
I. Remove the literature,
and then
close the door.
Do not load anything
in the drum for this test, as in
may affect the accuracy of the results.
4, Checkthe
displayfor
results.
During the three minute test cycle, monitor
the
Flow Sense TM display on the control panel. If no bars
are displayed, when the cycle ends, the exhaust
system is adequate.
If the exhaust system is severely
restricted,
the display will show four bars. Other
problems
may also be shown with error codes. Refer
to the next page for error code details and solutions.
NO BARS:
FOUR BARS:
OK
RESTRICTED
Four bars indicates that the exhaust system is severely
restricted. Have the system checked immediately,
as
performance
will be poor.
S, End of cycle.
At the end of the test cycle, _
will display.
The test cycle will end and the_
will shut off
automatically
after a short delay.
2, Press and hold the Temp.Control
and Signal
buttons
and then press the POWER button.
This button
sequence activates the installation
test.
The code |
will display if the activation
is
successful.
3. Press START/PAUSE button.
The dryer will start the test, which will last about
two minutes.
The heat will be turned on and the
temperatures
in the drum will be measured.