5 - 22 DS3578 With FIPS Digital Scanner Product Reference Guide
Decode Session Timeout
Parameter # 88h
This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in
0.1 second increments from 0.5 to 9.9 seconds. The default timeout is 9.9 seconds.
To set a Decode Session Timeout, scan the bar code below. Next, scan two numeric bar codes from
Numeric Bar Codes
example, to set a Decode Session Timeout of 0.5 seconds, scan the bar code below, then scan the 0 and 5 bar
codes. To correct an error or change the selection, scan
Decode Session Timeout
Timeout Between Decodes, Same Symbol
Parameter # 89h
Use this option in Continuous Bar Code Read mode to prevent the beeper from continuously beeping when a
symbol is left in the digital scanner's field of view. The bar code must be out of the field of view for the timeout
period before the scanner will read the same consecutive symbol. It is programmable in 0.1 second increments
from 0.0 to 9.9 seconds. The default interval is 0.5 seconds.
To select the timeout between decodes for the same symbol, scan the bar code below, then scan two numeric bar
codes from
Appendix E, Numeric Bar Codes
that correspond to the desired on time. Enter a leading zero for single digit numbers. For
that correspond to the desired interval, in 0.1 second increments.
.
Cancel on page D-7
Timeout Between Decodes, Same Symbol
Appendix E,