Item No.
U604
Setting user data 2
Description
Makes user settings to enable the use of the machine as a fax.
Purpose
Use this if the user wishes to adjust the number of rings that occur before the unit switches into
fax receiving mode when fax/telephone auto-select is enabled.
Method
1. Press the start key.
2. Select [RINGS(F/P)#].
3. Change the setting using the cursor left/right keys or numeric keys.
Description
Number of fax/telephone rings
* : If you set this to 0, the unit will start fax reception without any ringing.
4. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U605
Clearing data
Description
Initializes data related to the fax transmission such as transmission history.
Purpose
To clear the transmission history.
Method
1. Press the start key.
2. Select [CLEAR COM.REC.].
3. Press the start key. Initialization processing starts. When processing is finished, [Completed]
is displayed.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Description
Setting range
0 to 15
1-3-47
2PK/2PL/2PM/2PN
Initial setting
2 (120 V)/1 (220-240 V)