Display Provided When Diag Started; When There Is No History Of Protection Function; When There Is A History Of Protection Function - Yamaha RX-V4600/DSP Service Manual

Av receiver/av amplifier
Table of Contents

Advertisement

RX-V4600/DSP-AX4600

• Display provided when DIAG started

The FL display of the main unit displays the protection
function history data and the version (1 alphabet) and the
DIAG menu [sub-menu (YSS 0dB) of DIAG menu No.1
DSP THROUGH] a few seconds later.

When there is no history of protection function:

When there is a history of protection function:

Cause: An excessive current flowed through the power
amplifier.
Turning on the power without correcting the abnormality
will cause the protection function to work immediately and
the power supply will instantly be shut off.
Note)
• Applying the power to a unit without correcting the
abnormality can be dangerous and cause additional
circuit damage.
• The output transistors in each amplifier channel
should be checked for damage before applying any
power.
• Amplifier current should be monitored by measuring
across the emitter resistors for each channel.
26
Opening message /
オープニング表示
When there is no history
of protection function
Version (1 alphabet)
プロテクション履歴が
バージョン (英1文字)
ない場合
After a few seconds
数秒後
When there is a history of protection
function due to excess current
過電流によるプロテクション
履歴がある場合
● ダイアグ起動時の表示
本体のFLディスプレイにプロテクション履歴情報とバー
ジョン (英1文字) が表示され、数秒後にダイアグメニュー
(No.1 DSP THROUGHのサブメニューYSS 0dB) になりま
す。
プロテクション履歴がない場合:
DIAG menu display /
ダイアグメニュー表示
プロテクション履歴がある場合:
Version (1 alphabet)
バージョン (英1文字)
原因: パワーアンプに過電流が流れた。
補足: パワートランジスタの電流を検出していますので、
電流検出トランジスタをチェックすれば異常チャン
ネルが特定できます。
異常状態のままパワーオンすると、瞬時にプロテクション
がかかり、すぐに電源が切れます。