Security Codes

The system supports up to 48 security codes, which can each be assigned one of 5 authority levels.
The authority level determines the functions a particular user code can perform as follows:
Authority Levels
Level
Installer (user 01)
Master (user 02)
Part. Programmer
(user 03/user 33)
0-User
1-Arm Only
2-Guest
3-Duress
4-Partition Prog.
Refer to the user guide for procedures on adding/deleting security codes. The following is a brief
description of how to add user codes.
Adding a User Code:
Deleting a User Code: Master/Part. Prog. code + [8] + 2-digit user no. + [#] [0]
Assigning Attributes: Master/Part. Prog.
† Partition Programmer cannot assign parititions.
Functions
perform all security functions except can disarm only if used to arm;
can enter program mode; cannot change hidden installer code (default=6321)
only one master code per system; can perform all security functions, add/delete
users in either partition, change master code, view event log, set system clock,
program keypad macro, program scheduled events, activate output devices
(triggers/relays)
same as Master, except add/delete users limited to assigned partition
only, where user 03 = partition 1; user 33 = partition 2
(these users can be assigned different authority levels, if desired)
perform security functions (arm, disarm, etc.) only; cannot add/delete users,
view event log, set system clock or program scheduled events
arm system only
can disarm the system only if it was used to arm the system
performs security functions, but also silently sends a duress message to the
central station; reports as zone 92
see Partition Programmer paragraph above; use to assign other user numbers
as partition programmers
Master/Part. Prog. code + [8] + 2-digit user no. + user's code
Attributes:
1 = Authority Level (0-4) [see Authority Level table above]
2 = Access Group (0-8)
3 = Active Partition(s) for this user (1, 2, 3 [common] ); enter partitions consecutively
if more than one and press [#] to end the entries
4 = RF Zone No. (assigns user number to button type zone for arm/disarm)
5 = Open/Close Paging (1 for yes, 0 for no)

System Operation

code + [8] + 2-digit user no. + [#] [attribute no.] + value