Chapter 1

Site Requirements

Safety

This document describes the installation site requirements that must be met prior to
installing the G10 Cable Modem Termination System (CMTS). These requirements and
recommendations are prerequisites to those instructions provided in the Juniper Networks
G10 CMTS Installation and Configuration manual.
The following guidelines are recommended to ensure the safety and protection of system
equipment and equipment installers.
Verify compliance with all pertinent local and national regulatory requirements
Only trained or certified personnel should be involved in the installation of the CMTS
Enforce the use of grounding straps to protect the CMTS equipment from electrostatic
discharge (ESD) damage
Leave all modules in the anti-static packaging until the time of installation
Position the CMTS equipment in a clear, dry, dust-free area
Use a minimum of 3 people to lift the chassis
High levels of electrical energy are distributed across the
system midplane. Be careful not to contact the midplane
connectors, or any component connected to the midplane,
with any metallic object while hot-swapping or servicing
components installed in the system.