Safety Considerations; Introduction - Carrier 58CVA Installation, Start-Up, Operating And Service And Maintenance Instructions

Variable-speed, 4-way multipoise
Table of Contents

Advertisement

NOTES:
1. Two additional 7/8-in. diameter holes are located in the top plate.
2. Minimum return-air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer's recommendations for equivalent diameters.
a. For 800 CFM-16-in. round or 14 1/2 x 12-in. rectangle.
b. For 1200 CFM-20-in. round or 14 1/2 x 19 1/2-in. rectangle.
c. For 1600 CFM-22-in. round or 14 1/2 x 23 1/4-in. rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific
use of single side inlets. The use of both side inlets, a combination of 1 side and the bottom, or the
bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM.

SAFETY CONSIDERATIONS

Only trained and qualified personnel should install, repair, or
service heating equipment. Untrained personnel can perform
basic maintenance functions such as cleaning and replacing air
filters.
Observe precautions in the literature, on tags, and on labels
attached to or shipped with the unit and other safety precautions
that may apply.
These instructions cover minimum requirements and conform to
existing national standards and safety codes. In some instances,
these instructions exceed certain local codes and ordinances,
especially those that may not have kept up with changing residen-
tial construction practices. We require these instructions as a
minimum for a safe installation.
Wear safety glasses and work gloves. Have fire extinguisher
available during start-up and adjustment procedures and service
calls.
This is the safety alert symbol . When you see this symbol on the
furnace and in instructions or manuals, be alert to the potential for
personal injury.
Understand the signal words DANGER, WARNING, CAUTION,
and NOTE. These words are used with the safety-alert symbol.
DANGER identifies the most serious hazards which will result in
severe personal injury or death. WARNING signifies a hazard
which could result in personal injury or death. CAUTION is used
to identify unsafe practices which would result in minor personal
injury or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability,
or operation.
1. Use only with type of gas approved for this furnace. Refer to
the furnace rating palte.
2. Install this furnace only in a location and position as specified
in the "Location" section of these instructions.
3. Provide adequate combustion and ventilation air to the furnace
space as specified in "Air for Combustion and Ventilation"
section.
A
B
C
Fig. 1—Dimensional Drawing
4. Combustion products must be discharged outdoors. Conect
5. Never test for gas leaks with an open flame. Use a commer-
6. Always install furnace to operate within the furnace's intended
7. When a frunace is installed so that supply ducts carry air
8. A gas-fired furnace for installation in a residential garage must
9. The furnace is not to be used for temporary heating of
The Series 100/A 4–way multipoise Category I furnace is CSA
(A.G.A. and C.G.A.) design-certified for natural and propane gas
and for installation in alcoves, attics, basements, closets, utility
rooms, crawlspaces, and garages. The furnace is factory-shipped
for use with natural gas. A CSA (A.G.A. and C.G.A.) listed gas
conversion kit is required to convert furnace for use with propane
gas. This furnace is not approved for installation in mobile homes,
recreational vehicles, or outdoors.
These furnaces shall not be installed directly on carpeting, tile, or
any other combustible material other than wood flooring. For
downflow installations, a factory accessory floor base must be
2
this furnace to an approved vent system only, as specified in
the "Venting" section of these instructions
cially available soap aolution made specifically for the detec-
tion of leaks to check all connections, as specified in the "Gas
Piping" section.
temperature-rise range with a duct system which has an
external static pressure within the allowable range, as speci-
fied in the "Start-Up, Adjustments, and Safety Check" section.
See furnace rating plate.
circulated by the furnace to areas outside the space containing
the furnace, the return air shall also be handled by duct(s)
sealed to the furnace casing and terminating outside the space
containing the furnace. See "Air Ducts" section.
be installed as specified in the warning box in the "Location"
section.
buildings or structures under construction. See page 5 caution
box.

INTRODUCTION

A02096