Undo the 3 pump screws (3, fig.
82).
Pull pump forward to remove.
Remove back of control box by
undoing 2 screws (1, fig. 78).
Disconnect pump supply plug and
lift clear of board.
Fit new `0' rings (supplied with
pump) to connecting tubes.
Reassemble in reverse order.
Recommision boiler (see Section 5).
7.15 Replacement of automatic
air release (fig. 82)
Turn off boiler as in Section 7.1.1.
Release CH water pressure and
drain boiler as in Section 7.1.2.
Remove front casing as in Section
7.1.3.
Lower front control panel as in
Section 7.1.6.
Unscrew cap (4) of auto air release
and remove inner components.
Replace with new inner compo-
nents and reassemble in reverse
order.
Refill and repressurise the boiler
(see Section 5.4).
7.16 Replacement of automatic
bypass
Turn off boiler as in Section 7.1.1.
Release CH water pressure and
drain boiler as in Section 7.1.2.
Remove front casing as in Section
7.1.3.
Lower front control panel as in
Section 7.1.6.
Remove spring clip (2, fig. 83) by
lifting upwards.
fig. 82
fig. 83
49