Push both buttons under the diag-
nostic display simultaneously.
The flow temperature will now be
displayed.
Reset the maximum hot water tem-
perature selector to the required
setting (see Section 5.15).

5.11 Functional checks

5.11.1 Introduction
The boiler display (8, fig. 43) normal-
ly indicates the primary flow tempera-
ture. Whilst this display is showing the
boiler has internally self checked and
is operating normally. However, if
desired, a functional check of the boi-
ler DHW and CH operation may be
carried out using the status mode of
the built in diagnostics.
5.11.2 Functional check of
DHW operation using
built in diagnostics
Set the boiler central heating con-
trol to the `Hot Water only' position
Enter status mode by pushing the
right hand diagnostic button once,
e.g. with the tip of a ballpoint pen
(1, fig. 43). The display should
now show `S.0'
Turn on a hot tap and draw water
at a high rate.
The display will now step through
the following codes:
S.10 - calling for operation: DHW.
(display duration: 1 sec)
S.11 - fan running and proving
(display duration: 4 -5 secs)
S.13 - ignition
(display duration: 10 secs max)
S.14 - burner operation: DHW
(display for duration of hot water
draw off)
Turn the hot water tap off. The bur-
ner should be extinguished and the
display will now step through the
following codes:
S.15 - pump and fan overrun
(display duration: 5 secs)
30
fig. 43