Summary of Contents for Siemens M105
Page 1
*LJDVHW
, 9 , The cordless USB interface for connecting PCs to Gigaset 3070/75isdn +RZWRXVHWKLVPDQXDO &RQWHQWV Operating Instructions Please read the safety ,QGH[ Note precautions outlined in these operating instructions before putting the unit into service!
Page 2
+RZWRXVHWKLVPDQXDO The following controls are available in Acrobat Reader or in the context menu (right mouse button): Click here when you see this hand. Contents Introduction ............9 What is a Gigaset M101 Data? .
Overview Front Operating LED, illuminated when power supply is active, see "LEDs" on page 20 Data LED, illuminated during data transfer operations Side Port for the USB cable Back...
The "Local adapter" is the adapter that performs all con- figurations (also for the "remote adapter"). This means that the Gigaset M105 Data setup routine does not have to be installed on the second PC in the case of a direct cable connection.
Gigaset telephony. Here, portable part is the same as handset. This is defined, for example, through the registration option. Only one Gigaset M105 Data "Portable part" can have an active connection to a Gigaset 3070/75isdn or a Gigaset M101/M105 Data "Base".
Switch on the PC. Insert the CD in the CD-ROM drive. Connect the USB port on the Gigaset M105 Data to the USB interface on your PCs by means of the USB cable provided. The hardware assistant appears on the screen.
Configuration Configuration The purpose of configuration is to register the Gigaset M105 Data unit at a Gigaset 3070/3075isdn base station, at a second Gigaset M105 Data or at a Gigaset M101 Data. You can only perform configuration with the configuration program.
Set Gigaset program at both PCs. Select the Local adapter tab at both PCs. Change the type of Gigaset M105 Data at one of the PCs from "Portable part" to "Base". Click the Register button at both PCs. At the PC connected to the "Base" type Gigaset M105 Data, a LED flash- es in sequence to signal that the unit is ready for registration.
After approx. 10 seconds, the LEDs indicate that the system is ready for registration by flashing in sequence. Start the Set Gigaset program at the PC connected to the Gigaset M105 Data unit. Select the Local adapter tab. The type is "Portable part".
Configuration program options Configuration program options General You will not need the majority of configuration options for the simple im- plementation of a Gigaset M105 Data unit downstream of a Gigaset 3070/ 3075. Starting the configuration program Under Start, select...
Status: display in the dialog box. Gigaset M105 Data can only be configured under these conditions. Your Gigaset M105 Data will automatically switch the adapter back to operating status at the end of the program. Lower section: DECT connection This section indicates whether a radio connection exists and if so, to which Remote adapter.
"Direct connection", the other adapter must also be switched to this mode. The appropriate switches are performed auto- matically if you select an operating mode for a Gigaset M105 Data unit. Setting the operating mode Open the...
Configuration program options Special settings for "Direct connection" mode In Direct connection mode, the fields in the lower section of the dialog box are activated: you can set the transmission parameters for the virtual COM port at the PC. Use the default settings if you do not want to change any other parame- ters.
Page 16
Data). Activating local flow control can help in the event of data transmis- sion problems (e.g. sending faxes, operating a serial printer). When local flow control is active, the Gigaset M105 Data unit connected to the V.24 terminal immediately stops outputting data in the direction of the terminal when a STOP signal is received and saves this data in its own memory.
PC or the modem alternately. It may also be necessary here to change the adapter type at one of the Gigaset M105 Data units. Ensure that the correct Gigaset M105 Data is connected at the PC. Select Change adapter type.
Configuration program options Registering a portable part Both adapters are powered. The Gigaset M105 Data unit is connected to Gigaset" program. the PC; start the "Set Select the Local adapter tab. The following dialog box appears: Up to six registered devices can be entered in the Registered adapter window.
Configuration program options Enter the PIN and click The portable part now searches for the base station and automatically registers at it. If registration is not possible (base station not in registration mode or not powered, incorrect PIN), the system will indicate the necessary steps for resolving this problem.
This tab is used for configuring the Remote adapter that is not connected to the PC. Registration must be performed first so that the two Gigaset M105 Data units can communicate. Remote adapter tab is only available after registration on Local adapter tab.
Configuration program options Changing the name As for local adapter, see "Changing the name" on page 15 Change PIN ... Click Change PIN ..Enter the old PIN (PIN: 1–8 digits, default: 0000) to obtain authorisation to change the PIN and press the tab key. Enter the new PIN and press the tab key.
Configuration program options LEDs There are two LEDs on the front of the Gigaset M105 Data unit. LED 1: Gigaset M105 Data status LED 1 indicates stand-by mode: LED 1 flashes slowly The adapter is searching for the partner or has not been registered.
Place the Gigaset M105 Data unit on a level, non-slip surface. The device feet do not leave any unsightly marks. However, in view of the many dif- ferent varnishes and polishes currently used for furniture, the possibility of marks being left cannot be ruled out.
Special features when connecting two Gigaset M105 or M101 Data units A Gigaset M105 Data unit is powered via the USB port but operates like a COM interface with regard to data. For this reason, the transmission rate is also provided.
Page 25
AVM compatible (PC): this is the operating mode for the local adapter. The Gigaset M105 Data unit determines the conditions on the serial interface in the same way as a modem. In addition to the data, the transmission parameters are also transmitted to the Re- mote adapter which then transfers the data to the connected device.
Tips&tricks, settings Tips&tricks, settings This section describes settings, implementation options and program- ming methods. Access to different V.24 terminals from a laptop: All terminals (PC, modem, Gigaset 3070/3075isdn) can be accessed from a laptop. Only one data connection at a time can ever be set up to a terminal. You must select the relevant connection partner in the configuration mask in order to switch between the various terminals.
Tips&tricks, settings Sequential access from multiple computers to a terminal: Multiple portable parts (PC, laptop) share a Gigaset 3070/3075isdn ba- se (modem). Only one data connection at a time can ever be set up from a "portable part to the terminal". Simultaneous access from both portable parts to the Gigaset 3070/ 3075isdn modem is not possible.
This accelerates fault detection and clearance. If this is not possi- ble, the precise configuration is to be examined. The Gigaset M105 Data unit can be set to a fixed baud rate (direct con- nection 115200 bps with HW handshake).
Page 29
Tips&tricks, settings Then set the port speed: The baud rate (max. 115200) and HW handshake (default setting) are set in this mask. If you can now transfer data from one PC to another, pro- ceed with the second step. Set the direct cable connection parameters Exit the terminal program at one of the PCs.
Page 30
Tips&tricks, settings Null-Modem Ca- Double-click the icon to expand the branch. The setting ble at COMx should be available. Select the appropriate COM port for your configuration and double-click it to open another subfolder. Back...
Page 31
Tips&tricks, settings This Modem tab contains the setting for the maximum speed. This should be set to 115200 bps. Activate Hardware under Use flow control in Connection > Advanced. Click to exit each window. Test the baud rate setting Open the direct cable connection program under Start...
Page 32
Tips&tricks, settings Select Change and activate Guest. Then enter the interface, e.g. Null- Modem Cable at COM To enable access by the other PC, the host (controlling party) and guest (accessing party) as well as the file and print sharing option must be ac- tivated.
Page 33
Tips&tricks, settings Click File and Print Sharing in the sub-window. Set the parameters here. If a change was made, new drivers are loaded and Windows must be restarted. If file and print sharing was already activate, the computer does not need to be restarted.
Page 34
Tips&tricks, settings If the system was not restarted, the following window appears: If file/printer sharing has not yet been activated, start to activate it, see "Sharing files" on page 33 In the final window, select Finish and click to answer the questions. A window entitled Direct Cable Connection with the status...
Tips&tricks, settings Sharing files Since the Windows information in the previous mask is somewhat confus- ing, and since no references are made to the File Manager/Explorer, here is the correct procedure. Once file sharing has been activated and the PC restarted, you can release files for processing by the other PC via the File Manager/Explorer.
Tips&tricks, settings Assign the other PC user access rights to the files on your hard disk, or where applicable, activate password protection. Files that support sharing are identified as follows: shared not shared Examples of PC-PC direct cable connection problems Other modem drivers installed continue to operate at the same COM port (special ISDN TA drivers, CAPI modem drivers or similar software are of- ten the cause of the problem).
If the malfunction persists after checking all the above points, call the hot- line at 0180 5 333 220. If you are in Austria and your unit is connected to a single connection, contact the Siemens hotline at 01/ 1707-5004 is connected to a telephone system, contact the relevant installation company, e.g.
If you have problems with this setting, start the configuration program and check the transmission quality under Connection and improve the quality of the connection by moving the Gigaset M105 Data unit slightly. Back...
16 PIN entered is rejected The PIN entered does not If you forgot the current PIN, reset match the valid PIN. the Gigaset M105 Data unit to the factory defaults. The preset PIN is "0000". Problems with application programs Fault...
Page 40
Cause Solution Monitor fault when Gigaset DECT HF wanted signals is in- Move Gigaset M105 Data M105 Data is active (e.g. slight fluencing the monitor. along the longitudinal axis until flickering or moiré effect). the interference disappears. Move Gigaset M105 Data fur- ther away from the monitor.
What happens if... Technical data Standard: DECT =Digital Enhanced Cordless Telecom- munications Number of channels: 120 duplex channels Radio frequency range: 1880 MHz to1900 MHz Transmitted power: 10 mW, average rating per channel Range: up to 300 m outdoors, up to 50 m indoors Power supply: USB powered Power consumption: Stand-by mode: approx.
Do not forget to include the operating instructions and CD when passing on Gigaset M105 Data to a third party. Gigaset M105 Data is designed for operation in your country as indicated on the back of the unit. Special country-specific features have been im- plemented.
Index Index Numerics Flow control 14 3070isdn/3075isdn 7 Hardware (RTS/CTS) 13 Adapter type, changing 15 Ambient conditions 21 Implementation options 24 AT commands 12 Initial configuration 7 AT commands or AVM compatible 23 Installation 6 Automatic enabling 17 Laplink 7.0 38 Base 5 Laptop 24 Baud rate, setting 26...
Page 44
Local adapter 15 Operating mode 12 Registering at 3070isdn/3075isdn 7 Remote adapter 18 Registering at Gigaset M101 Data 9 Tips 24 Registering at Gigaset M105 Data 8 Registration not possible 37 Remote adapter USB bus cable and M105 de-registering registering 16 Request To Send 13 What happens if...