Tree Survey Error Messages And Notices - Panasonic KX-UDS124 Maintenance Tool Manual

Hide thumbs Also See for KX-UDS124:
Table of Contents

Advertisement

4.2.1. Tree Survey Error Messages and Notices

When an error occurs during or after the Tree Survey, an error message or notice is displayed.
Messages displayed during the Tree Survey
Message
Monitoring error because air
synchronization has not
been established.
Connection error.
Messages displayed when the Tree Survey is complete
Message
Notice Sync Slave CS does
not have Secondary CS.
ERROR!!! CS does not
have Primary CS.
ERROR!!! Survey result
contains more than 9
levels.
ERROR!!! Unknown error
code.
Probable Cause
Slave CS cannot receive radio
signal from another Air Sync
Group CS.
IP network environment and settings
are incorrect.
Probable Cause
One or more SIP-CSs could not have
a Slave CS assigned for reasons
such as avoiding the creation of a
loop. However, this is not a problem.
A SIP-CS is located far from the
adjacent SIP-CS.
Air synchronization hierarchy
contains more than 9 levels.
Tree Survey failed for some reason.
14
Solution
Please check whether a radio
signal obstacle, such as a metal
shelf, a door, etc., exists near the
SIP-CS.
Please check the network connection
of the SIP-CS(s) and PC.
Solution
Please move the SIP-CS(s) closer to
the adjacent SIP-CS according to site
planning.
Loops may occur when SIP-CSs are
assigned a Slave CS. In this case,
please reconduct site planning.
Please move the SIP-CS(s) closer to
the adjacent SIP-CS according to site
planning.
Please recheck the design of your
Tree Structure and relocate
SIP-CS(s) to remove the
unsupported level(s).
Conduct the Tree Survey again.

Advertisement

Table of Contents
loading