Installation sequence
Installing the external unit
B Gravel bed as condensate soak-
away
C Concrete foundations (see technical
guide)
D Drainage pipe DN 100 (only with
entries below ground level)
Note
We recommend letting condensate drain
away freely (without condensate pipe).
Wall mounting
Installation must only be performed with
the bracket set suitable for wall mounting
(accessory).

Installing the internal unit

!
Please note
Avoid damaging the appliance
during transportation.
Never put weight on top of the
appliance.
Installation room requirements
!
Please note
The installation room must be dry
and free from the risk of frost.
Safeguard ambient temperatures
between 0 and 35 °C.
!
Please note
Avoid the risk of explosion due to
dust, gases and vapours
in the installation room.
14
(cont.)
E Rubber mounts (supplied)
Separate installation instructions
Minimum room volume (to EN 378):
Type AWB/AWB-
AC
201.B04
201.B07
201.B10
201.B13
201.C10
201.C13
Minimum room
3
volume in m
2.7
4.8
6.7
6.7
6.7
6.7