CARE & CLEANING Continued
Remove and clean the grid rack inserts and grease drip chute
daily. Pull the grid rack forward and lift the grease rack insert
out of the frame. Remove the grease drip chute by pulling it
forward out of the rack frame guides.

M110XM

The M110XM fi lter should be removed and cleaned every
one to two days, depending on usage. The fi lter can be
cleaned by hand with dish detergent or run though the
dishwasher.

M100X (R/RC/S/TM)

The M100 series of broilers have an air fan assisted motor
with a stainless steel fi lter screen to ensure a clean source of
primary air for your broiler burner combustion system. The
fi lter screen is located internally in the unit behind the broiler
grease tray assembly. It is recommended that you have your
service technician remove, clean and inspect this fi lter screen
when you do you regular equipment maintenance.
Grease Filter Removal on the M100X's
1. It is recommended that this procedure be done when the
range is cool and not in use.
2. Remove all the control knobs.
3. Remove the grease tray.
4. Remove the screws for the valve panel and then remove
this panel.
5. Reach inside to access the grease fi lter screen. (Located
behind the grease tray area.) The protective cover over the
fi lter screen will snap off by carefully pulling downward by
hand.
6. Rinse the fi lter cover and fi lter with warm water and base
dish detergent soap.
7. Dry the fi lter screen and cover, then carefully snap back in
place.
8. Return the valve control panel with screws.
9. Ensure the grease tray has been replaced back into
position.
10. Carefully place the control knobs back into position.
Part # 4515576 Rev 1 (01/21/10)
Instructions For Removal Of Grid Rack &

Grid Rack Frame

Remove the broiler grid racks as follows:
1. Bring the grid rack down to the lowest adjustment
position.
2. Pull the entire grid rack out of the broiler as far as
possible.
3. Remove grid rack grease drip chute (located below wire
rack) by grasping hold of the chute and pulling forward
out of the frame guides.
4. Remove wire racks by lifting the front of each wire rack
over the rack front plate.
5. Pull the empty grid rack frame assembly as far forward
as possible (until the stops hit the front of the carriage
assembly), lift up on the handle and pull the rack
frame forward so the stops clear the carriage assembly.
Continue pulling the rack frame forward until the rear
bearings reach the notches in the carriage tracks and lift
the rear of the rack up and out of the carriage; the entire
frame is now free from the unit.
6. Place the rack raising lever in the highest position for
safety purposes.
Before cleaning the hopper, replace the grease drawer
to receive any drippings and solid particles freed by the
cleaning. The additional internal grease diverter should be
removed from the top section and cleaned at this time. The
diverter is removed by raising the rack assembly and lifting
up the front of the diverter. After disengaging the screws at
the front of the unit, pull the diverter forward and remove
from the unit.
Carriage mechanisms should be kept clean, particularly
around the roller bearings. If the roller bearings have been
washed clean or appear to be dry, they should be lubricated
using salt-free vegetable oil or a non-toxic high temperature
bearing lubricant.
Infra-Red Burners must be cleaned periodically by a service
professional.