Kenwood TK-3207 Service Manual page 42

Hide thumbs Also See for TK-3207:
Table of Contents

Advertisement

TK-3207
Item
Condition
2.Sensitivity
TEST CH: Low
check
[Wide]
SSG otuput:–117 dBm(0.3µV) AF VTVM
SSG MOD:3.0kHz
[Narrow]
TEST CH:Center
SSG otuput:–115 dBm(0.4µV)
SSG MOD:1.5kHz
3.SQL1
TEST CH: Center
(Threshold)
writing
[Wide]
SSG otuput:–123 dBm(0.16µV)
SSG MOD:3.0kHz
[Narrow]
TEST CH: Center
SSG otuput:–122 dBm(0.18µV)
SSG MOD:1.5kHz
4.SQL9
TEST CH: Center
(Tight)
writing
[Wide]
SSG otuput:–117 dBm(0.3µV)
SSG MOD:3.0kHz
[Narrow]
TEST CH: Center
SSG otuput:–116 dBm(0.35µV)
SSG MOD:1.5kHz
5.BATT
BATT terminal voltage:5.9V
Detection
Writing
42
ADJUSTMENT /
Measurement
Test equipment
SSG
Center
DVM
High
Oscilloscope
Low
High
Low
High
DVM
调整
Adjustment
Terminal
Parts
ANT
Programming
Software:
KPG-87D
ANT
BATT terminal
Specifications/
Remark
Method
Check
12dB SINAD or more
Write
Squelch open
Write
BATT terminal
voltage:5.9V