Determines whether the Tio1608-D OUTPUT ports are connected to the console when
the console is turned on and Quick Config is enabled.
When the checkbox is turned on and if Quick Config is enabled, the Tio1608-D and the
console are patched automatically.
This checkbox can be turned on and off when the Quick Config button is turned off.
NOTE
• When Quick Config is enabled, only one TF series console on the network can use the Tio1608-D
OUTPUT ports. If one or more other Tio1608-D units on the network have OUTPUT ports used by
another TF series console, the with OUTPUT checkbox turns off automatically and a popup screen
is displayed.
• When the with OUPUT checkbox is turned off and you are using Dante Controller for patching, refer
to "Quick Config Input and input channel relationships"
assignments for channels.
9
HA Control button
Determines whether the head amp of the Tio1608-D is controlled by the console.
Displayed in gray when turned off, and white when turned on.
When turned off, analog gain and +48V phantom power is disabled for input channels
set to SLOT.
NOTE
When there are multiple host devices on the same network that can control the head amp, repeated
operations could result, therefore we recommend having only one host device control the head amp.
0
Channel display area
The following information is displayed when the console's Quick Config button is turned
on and a Tio1608-D with the [QUICK CONFIG] switch turned on is connected.
• CH Name
• CH Color
• +48V setting for each channel (the indicator below and to the left of the channel icon
lights in red when turned on)
(page
91) for information about output port
- 24 -
RECALL SAFE screen
Allows you to configure which items are recalled and which items are not (i.e., recall safe)
when recalling Scenes and Presets.
"Recall safe" allows you to select certain parameters, channels, DCA groups, etc. whose
settings will not be replaced when recalling a Preset or Scene.
1
Channel selection buttons
Allows you to select which types of channels will be configured.
When you select a channel type, the different parameters that can be configured as
recall safe are displayed.
2
Parameter names
Touch the M button to turn SAFE parameters on and off for all channels of the same type.
The M button turns green when all SAFE parameters are turned on. If turned off for a parameter
on all channels, it is displayed in gray. Finally, if recall safe is turned on for a parameter
but not for all channels, the M button under the parameter name is displayed in blue.
3
Recall safe on/off buttons
Turns recall safe on and off for the corresponding parameter. When turned on, the
corresponding parameter is recall safe, i.e., its setting will not be changed when a Preset
or Scene is recalled.
For OMNI OUT assignments, recall safe can be turned on and off for OMNI OUT PATCH
only.
4
Channel information
Displays the channel ID, name, and icon.
Touch the SAFE button to turn safe recall on and off for the corresponding channel.
When turned on, parameters whose recall safe on/off buttons are in the "on" position
will not be recalled.