Superior PHK30 Installation And Operation Instructions Manual page 7

Table of Contents

Advertisement

N.G.
Burner Orifice Sizing
Log Size
18"
0.120
24"
0.140
CHECK GAS TYPE
30"
0.1495
Use only natural gas. If your gas supply is
Figure 2 - Technical Information Charts
not natural gas, you MUST NOT install this
CHECK GAS TYPE
log set.
Use only natural gas. If your gas supply is
If the fireplace does not have a gas supply
not natural gas, you MUST NOT install this
shutoff valve, one must be installed.
gas log set.
WARNING: This appliance is
equipped for natural gas. Field
conversion is not permitted.
If fireplace does not have a gas supply shutoff
VENTING SPECIFICATIONS FOR
valve, one must be installed.
INSTALLATION
VENTING SPECIFICATIONS FOR
The fireplace chimney flue and vent must be
INSTALLATION
drafting properly. To check the vent for proper
Fireplace chimney flue and vent must be draft-
drafting: Light a tightly rolled newspaper on
ing properly. To check vent for proper draft-
one end and place it at the inside front edge
ing: Light a tightly rolled newspaper on one
of the fireplace. Observe the smoke and be
end and place inside front edge of fireplace.
sure the vent is properly drawing it up the
Observe smoke and be sure vent is properly
chimney. If the smoke spills out into the room,
drawing smoke up chimney. If smoke spills out
extinguish the flame and remove any obstruc-
6
tion until proper venting is achieved.
The chimney flue must remain open a mini-
mum of 3" at all times during the operation
of this log set.
INSTALLING DAMPER CLAMP
Damper
Clamp
Damper
Clamp
Damper
Masonry Fireplace
Figure 3 - Attaching Damper Clamp
Secure the damper stop clamp provided to
the leading edge of the damper as shown in
Figure 3. If for any reason this clamp doesn't
work on your fireplace, another suitable clamp
or permanent stop must be installed or the
damper blade must be cut or removed.
126903-01A
5.5"
10.5"
Natural Gas
In.
Num.
INSTALLATION
31
28
25
www.fmiproducts.com
Damper
Damper
Manufactured Fireplace
www.SuperiorFireplaces.US.com
Damper
Continued
CONNECTING TO GAS SUPPLY
Masonry
Fireplace
WARNING: A qualified ser-
Figure 3 - Attaching Damper Clamp
vice person must connect log
CONNECTING TO GAS SUPPLY
set to gas supply. Follow all
local codes.
WARNING: A qualified ser-
vice person must connect log
Installation Items Needed
set to gas supply. Follow all
Before installing log set, make sure you have
the items listed below.
local codes.
• piping (check local codes)
Installation Items Needed
• sealant (resistant to propane/LP gas)
Before installing log set, make sure you have
• equipment shutoff valve
the items listed below.
• test gauge connection
• piping (check local codes)
• adjustable (crescent) wrench or pliers
• sealant (resistant to Propane/LP gas)
• sediment trap
• equipment shutoff valve
• tee joint
• test gauge connection
• pipe wrench
• adjustable (crescent) wrench or pliers
• sediment trap
CAUTION: Use only new,
• tee joint
black iron or steel pipe. Inter-
• pipe wrench
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of
1/2" diameter or greater to allow
proper gas volume to log set. If
pipe is too small, undue loss of
volume will occur.
Approved
Flexible Gas
Hose
(if allowed
by local
codes)
3" Minimum
Figure 4 - Gas Connection
* Purchase the optional equipment shutoff
valve from your dealer.
** Minimum inlet pressure for purpose of input
adjustment.
Damper
Manufactured
Fireplace
115425-01F
Equipment Shutoff Valve
With 1/8" NPT Tap*
From Gas
Meter
(5" W.C.** to
10.5" W.C.
Pressure)
Cap
Pipe
Tee
Nipple Joint
Sediment Trap
7