WARNING: Before installing
in a solid fuel burning fireplace,
the chimney flue and firebox
must be cleaned of soot, creo-
sote, ashes and loose paint by a
qualified chimney cleaner. Creo-
sote will ignite if highly heated.
A dirty chimney flue may create
and distribute soot within the
house. Inspect chimney flue and
firebox for damage. If damaged,
repair flue before operating ap-
pliance.
NOTICE: Installation, service
and repair of this appliance must
be performed by a qualified in-
staller, service agency, company
or gas supplier experienced with
this type of gas appliance. Only
factory authorized components
listed in these instructions may
be used in accordance with the
manufacturer's instructions
and all codes and requirements
of the authority having juris-
diction. Any modifications to
this kit or use of unauthorized
components or accessory items
will void the manufacturer's
warranty and may result in a
hazardous condition.
6

INSTALLATION

www.SuperiorFireplaces.US.com
FLUE OPENING SPECIFICATIONS
Note: This vented appliance must be installed
only in a solid-fuel burning fireplace with a
working flue and constructed of noncombus-
tible material.
The charts in Figure 2 indicate technical
information regarding the installation of your
gas log set. Please make sure that all of the
specifications shown are applicable before
installation is attempted.
The fireplace must include a working flue and
venting system with the minimum openings
shown in the Figure 2.
Burner
Model
Description
PHK18
18" Ramp
BCS18
PHK24
24" Ramp
BCS24
PHK30
30" Ramp
BCS30
Minimum Fireplace Dimensions
Front
Model
Width
PHK18
28"
BCS18
PHK24
36"
BCS24
PHK30
42"
BCS30
* At depth Indicated
Fuel Inlet Pressure
Specifications (W.C.)
N.G.
Burner Orifice Sizing
Log Size
18"
0.120
24"
0.140
30"
0.1495
Figure 2 - Technical Information Charts
CHECK GAS TYPE
Use only natural gas. If your gas supply is
not natural gas, you MUST NOT install this
gas log set.
WARNING: This appliance is
equipped for natural gas. Field
conversion is not permitted.
INSTALLATIO
BTU Input
Minimum
(Natural
Flue
Gas)
Opening
57,000
80,000
90,000
Back
Depth
Height
Width*
18"
16"
23"
16"
29"
18"
Min.
Max.
5.5"
10.5"
Natural Gas
In.
Num.
31
28
25
126903-01A
Continued
into roo
obstruc
Chimne
3" at al
8"
INSTA
8"
Secure
leading
8"
3. If for
on you
perman
blade m
For Ma
stallatio
18"
Commo
dampe
18"
in fully
18"
Dampe
Clamp
M
Fi
Figu
CONN
W
vice
set
loca
Installa