CCI Pro 700 • Setup Guide
Overview
The Extron CCI Pro 700 TouchLink Pro Conference Room Control Interface is a tabletop dialing interface for conferencing,
collaboration, and AV control. It is fully compatible with Extron IPCP Pro and IPL Pro control systems and is configured using
Extron GUI Designer and Extron Global Configurator Plus and Professional. See the Extron website for more information about
the software. This guide provides instructions for an experienced installer to install and connect the CCI Pro 700.
Setup Checklist
Download and install GUI Designer and Global Configurator Plus and Professional (available at www.extron.com) on a
computer connected to the same network as the CCI Pro 700.
Obtain the following network information from the network administrator.
DHCP status (on or off). If DHCP is off, you will also require the following:
IP address
Installation
Mount the Interface
Place the interface on a flat surface, like a tabletop. Ensure the desired network
cable can reach the location.
Cable the Interface
Hold the base and pull the tab on the top of the interface (
1.
device from the base.
Pull the interface away from the base and set it aside.
2.
Route a straight-through Ethernet cable through the opening in the base (
3.
Connect the Ethernet cable to the RJ-45 connector on the rear panel (
4.
Route the Ethernet cable along the designated path on the rear panel (
5.
If necessary, configure the device prior to reconnecting the interface to the base
6.
(see
Configuration
Press the interface back into the base.
7.
Power the Interface
The CCI Pro 700 requires power over Ethernet. If necessary, include a power injector (not provided) along the Ethernet cable run
to power the interface (see the power injector user guide for more details).
ATTENTION:
The CCI Pro 700 is intended for connection to a Power over Ethernet circuit for intra-building use only and is
considered to be part of a Network Environment 0 per IEC TR62-101.
Le CCI Pro 700 est conçu pour une connexion à un circuit PoE pour une utilisation intérieure seulement et est
considéré comme faisant partie d'un environnement réseau 0 par IEC TR62101.
Power over Ethernet (PoE) is intended for indoor use only. It is to be connected only to networks or circuits that are not
routed to the outside plant or building.
L'alimentation via Ethernet (PoE) est destinée à une utilisation en intérieur uniquement. Elle doit être connectée
seulement à des réseaux ou des circuits qui ne sont pas routés au réseau ou au bâtiment extérieur.
To use a power injector, connect a straight-through Ethernet cable to the power supply
and a switch or router. This cable carries network information from the switch or router
to the power injector input. Connect a second straight-through cable between the power
injector and the CCI Pro 700 to carry the network information and 48 VDC from the power
injector to the interface. Connect the IEC power cord to a convenient 100 VAC to
240 VAC, 50-60 Hz power source. The image to the right shows the Extron XTP PI 100.
Subnet mask
on page 2).
Gateway address
1
) to dislodge the
1
).
2
3
).
4
).
Base
2
3
~
100-240V
50-60Hz
0.4A MAX
XTP
XTP PWR
PWR
To a network switch
To the CCI Pro 700
Interface
4
1

Advertisement

loading

Summary of Contents for Extron electronics CCI Pro 700

  • Page 1 Press the interface back into the base. Power the Interface The CCI Pro 700 requires power over Ethernet. If necessary, include a power injector (not provided) along the Ethernet cable run to power the interface (see the power injector user guide for more details).
  • Page 2 The setup menu provides local, basic configuration options for the CCI Pro 700. When the CCI Pro 700 is initially powered on, use the setup menu to establish network settings, set display settings, set the output volume, and set a lockout PIN.
  • Page 3: Network Settings

    Network settings The Network submenu contains options over two pages to configure network communication settings. To access the Network submenu, highlight Network on the main menu and press the Navigation button. To configure the network settings for use with DHCP: Highlight DHCP and press the ◄...
  • Page 4 Extron USA - West Extron USA - East +1.714.491.1500 +1.919.850.1000 +31.33.453.4040 +91.80.3055.3777 +1.714.491.1517 FAX +1.919.850.1001 FAX +31.33.453.4050 FAX +91.80.3055.3737 FAX 68-2785-50 Rev. A © 2016 Extron Electronics All rights reserved. All trademarks mentioned are the property of their respective owners. www.extron.com 03 16...