Pole Mount Installation - Bosch ISC-FPB1-W60QS Installation And Operation Manual

Photobeam 5000
Table of Contents

Advertisement

10
en | Installation
Distance, horizontal and vertical spread values: (A) / (B) / (C)
Metric
20 m / 0.5 m / 0.8 m
40 m / 1.0 m /1.3 m
60 m / 1.5m / 1.8 m
80 m / 2.0 m / 2.2 m
100 m / 2.5 m / 2.7 m
120 m / 3.0 m / 3.2 m
140 m / 3.5 m / 3.7 m
160 m / 4.0 m / 4.2 m
180 m / 4.5 m / 4.7 m
200 m / 5.0 m / 5.2 m
3.2

Pole mount installation

1
Figure 3.2: Pole mounting view
Callout ﹘ Description
1 ー Diameter 38.0 – 42.7 mm (1.50 – 1.68
in)
Attaching the mounting bracket:
1.
2.
3.
4.
2016.02 | 03 | F.01U.305.910
Choose an appropriate mounting location for the devices. Install the mounting poles with
a clear line-of-sight between the transmitter and receiver.
Loosen the transmitter's cover mounting screw and remove the cover.
Loosen the two base mounting screws and remove the mounting plate by sliding it down.
Attach the mounting hardware to the mounting plate using the clamping screws. Refer to
the figure below.
Installation and Operation Guide
Imperial unit
65 ft / 1.6 ft / 2.6 ft
13.1 ft / 3.2 ft / 4.2 ft
196 ft / 4.9 ft / 5.9 ft
262 ft / 6.5 ft / 7.2 ft
328 ft / 8.2 ft / 8.8 ft
393 ft / 9.8 ft / 10.4 ft
459 ft / 11.4 ft / 12.1 ft
524 ft / 13.1 ft / 13.7 ft
590 ft / 14.7 ft / 15.4 ft
656 ft / 16.4 ft / 17.0 ft
2
Callout ﹘ Description
2 ー Back-to-back pole mounting
Photobeam 5000
Bosch Security Systems, Inc.