8. "+X" is displayed. Main unit is fixed so that 1 of fig.1 may
become downward and press the [
EL display
+X
9. "+Y" is displayed. Main unit is fixed so that 3 of fig.1 may
become downward and press the [
EL display
+Y
10. "CALIB" is displayed. Press the [
Then "FIN", "DAT NG" or "SEN NG" is displayed automatically.
(Press the [BACK] key, return to minor item selection screens)
EL display
CALIB
FIN
FIN
: Normally completing.
DAT NG : The data for performing a calibration is faulty.
SEN NG : The value acquired from the G-sensor is faulty.
11. The offset and the sensitivity of each axis are displayed by
pressing the [
]
key when normally completing in order of X,
u
Y and Z.
EL display
*** ##
*** : offset, ##: sensitivity
12. Press the [BACK] key, return to minor item selection screen.
Fig.1 Axis direction of G-sensor adjustment
6
2
16
]
key.
u
]
key.
u
]
key, G-sensor is adjusted.
u
r
4
1
5
3
5-3-6. G-sensor adjustment check
This mode checks that G-sensor adjustment is performed or not
performed.
Checking method:
1. Enter the test mode.
2. Press the [ ]
key to display major item, and press the [ ]
B
key to select the "OTHERS".
EL display
OTHERS
3. Press the [ ]
key to display minor item, and press the [ ]
B
key to select the "G CHK".
EL display
G CHK
4. Press the [
]
key, "START" is displayed. Then "OK" or "YET"
u
is displayed automatically.
EL display
START
OK
5. Press the [BACK] key, return to minor item selection screen.
/ [ ]