• Test Modes for grid load testing. The left display will show "tESt"
and "LoAd" alternately at 0.5 second intervals. The right display
will show "CC" (mode 200)(Figure B.9), "CV" (mode 201)(Figure
B.10) or "OFF" (normal operation)(Figure B.11). This setting is
not remembered between machine power cycles and will default
to OFF at each power on. Moving the position of the weld process
selection rotary switch Item 10 will reset the setting back to OFF.
FIGURE B.9
EXITING HIDDEN MENU BUTTON
Pressing and holding the hidden reset push button for 5 seconds will
cause certain stored values to be reset to defaults. The stored hot
start values will return to a default setting of 5 on the display (0 at the
attribute). The work point values will all be reset to the minimum
from the weld table for each respective weld mode. The alternate CV
mode selection will revert back to the Flux-Cored Arc Welding-Self
Shielding (FCAW-SS) setting. The remote pot connector choice will
revert back to the 12-pin connector. When the reset occurs, the left
display will show " deF", and the right display will show "AuLt" for 3
seconds until the machine exits the menu system.
FIGURE B.10
FIGURE B.11