Lincoln Electric VANTAGE 600 SD Operator's Manual page 34

11981
Table of Contents

Advertisement

®
VANTAGE
600 SD
TABLE B.5 VANTAGE
WELD
AMPS
WATTS
0
12,000
100
12,000
PLUS
200
12,000
250
12,000
300
10,000
400
up to 600
TABLE B.6 VANTAGE
Current
Voltage
Load
(Amps)
(Volts)
(Watts)
15
120
1800
15
240
3600
20
120
2400
20
240
4800
25
240
6000
30
240
7200
38
240
9000
50
240
12000
®
600 SD DEUTZ SIMULTANEOUS WELDING AND POWER LOADS
1 PHASE
AMPS
50
50
OR
50
50
42
5,600
23
0
0
®
600 SD DEUTZ Extension Cord Length Recommendations
Maximum Allowable Cord Length in ft. (m) for Conductor Size
14 AWG
12 AWG
30
(9)
40
(12)
60
(18)
75
(23)
30
(9)
60
(18)
Conductor size is based on maximum 2.0% voltage drop.
3 PHASE
WATTS
AMPS
20,000
50
17,800
43
14,000
34
OR
12,000
29
10,000
24
5,600
13
0
0
10 AWG
8 AWG
75
(23)
125
150
(46)
225
50
(15)
88
100
(30)
175
90
(27)
150
75
(23)
120
100
B-15
BOTH 1 AND 3 PHASE
WATTS
AMPS
------
50
------
50
------
50
12,000
------
10,000
------
5,600
------
0
0
6 AWG
(38)
175
(53)
300
(69)
350
(107)
600
(27)
138
(42)
225
(53)
275
(84)
450
(46)
225
(69)
250
(37)
175
(53)
300
(30)
150
(46)
250
125
(38)
200
OPERATION
4 AWG
(91)
(183)
(69)
(137)
(76)
(91)
(76)
(61)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents