Planet LRP-822CS Quick Installation Manual

Multi-port coax + 2-port 10/100/1000t + 2-port 100/1000x sfp long reach poe over coaxial managed switch
Hide thumbs Also See for LRP-822CS:

Advertisement

Quick Links

Multi-port Coax + 2-port 10/100/1000T + 2-port
100/1000X SFP Long Reach PoE over Coaxial
Managed Switch
LRP-822CS / LRP-1622CS
Quick Installation Guide

Advertisement

Table of Contents
loading

Summary of Contents for Planet LRP-822CS

  • Page 1 Multi-port Coax + 2-port 10/100/1000T + 2-port 100/1000X SFP Long Reach PoE over Coaxial Managed Switch LRP-822CS / LRP-1622CS Quick Installation Guide...
  • Page 2: Table Of Contents

    Table of Contents 1. Package Contents ..................3 2. Requirements ..................... 4 3. Terminal Setup ................... 5 4. Logon to the Console .................. 6 5. Configuring IP Address via the Console ............7 6. Saving the Configuration via the Console ............9 7. Starting Web Management .................10 8. Starting Long Reach PoE Communication .............12 9. Saving Configuration via the Web ...............16 10. Recovering Back to Default Configuration ............17 11.
  • Page 3: Package Contents

    Open the box of the LRP Managed Switch and carefully unpack it. The box should contain the following items: z The LRP Managed Switch x 1 z Quick Installation Guide x 1 z Rubber Feet x 4 z Power Cord x 1 z RS232 to RJ45 Console Cable x 1 z SFP Dust Cap x 2 z BNC Female Dust Cap x 8 (LRP-822CS) z BNC Female Dust Cap x 16 (LRP-1622CS) z Warning Sticker x 8 (LRP-822CS) z Warning Sticker x 16 (LRP-1622CS) z Rack-mount Accessory Kit x 1 If any item is found missing or damaged, please contact your local reseller for replacement.
  • Page 4: Requirements

    2. Requirements z Workstations running Windows XP/2003/Vista/7/8/2008, MAC OS X or later, Linux, UNIX, or other platforms are compatible with TCP/IP protocols. z Workstations are installed with Ethernet NIC (Network Interface Card) z Serial Port Connection (Terminal)  The above Workstations come with COM Port (DB9) or USB-to-RS-232 converter.  The above Workstations have been installed with terminal emulator, such as Hyper Terminal included in Windows XP/2003.
  • Page 5: Terminal Setup

    3. Terminal Setup To configure the system, connect a serial cable to a COM port on a PC or notebook computer and to the RJ45 type of the console port of the LRP Managed Switch. PC / Workstation with Terminal Emulation Software Managed Switch RS232 to RJ45 Cable Serial Port...
  • Page 6: Logon To The Console

    4. Logon to the Console Once the terminal is connected to the device, power on the LRP Managed Switch, and the terminal will display “running testing procedures”. Then, the following message asks to log-in user name and password. The factory default user name and password are shown as follows, and the login screen in Figure 4-1 appears.
  • Page 7: Configuring Ip Address Via The Console

    5. Configuring IP Address via the Console The LRP Managed Switch is shipped with default IP address as follows: IP Address: 192.168.0.100 Subnet Mask: 255.255.255.0 To check the current IP address or modify a new IP address for the Switch, please use the procedures as follows:  Show the current IP address 1. At the “LRP-series#” prompt, enter “show ip”. 2. The screen displays the current IP address, Subnet Mask and Gateway as shown in Figure 5-1. Figure 5-1: IP Information Screen  Configuring IP address 3. At the “LRP-series#” prompt, enter “configure”. 4. At the “LRP-series (config)#” prompt, enter the following command and press <Enter> as shown in Figure 5-2.
  • Page 8 The previous command would apply the following settings for the Switch. IP Address: 192.168.1.100 Subnet Mask: 255.255.255.0 Gateway: 192.168.1.254 Figure 5-2: IP Address Screen 5. Repeat Step 1 to check if the IP address is changed. If the IP is successfully configured, the LRP Managed Switch will apply the new IP address setting immediately. You can access the Web interface of the LRP Managed Switch through the new IP address. If you are not familiar with console command or the related parameter, enter “?” anytime in console to get the help description. Note...
  • Page 9: Saving The Configuration Via The Console

    6. Saving the Configuration via the Console In the switch, the running configuration file stores in the RAM. In the current version, the running configuration sequence running-config can be saved from the RAM to FLASH by writing the command or copying the running-config startup- config command, so that the running configuration sequence becomes the startup configuration file, which is called configuration save.
  • Page 10: Starting Web Management

    7. Starting Web Management The following shows how to start up the Web Management of the LRP Managed Switch. Note the LRP Managed Switch is configured through an Ethernet connection. Please make sure the manager PC must be set on the same IP subnet address.
  • Page 11 3. After entering the password, the main screen appears as Figure 7-3 shows. Figure 7-3: Web Main Screen of LRP Managed Switch The Switch Menu on the left of the Web page lets you access all the commands and statistics the LRP Managed Switch provides. Figure 7-4: Switch Menu Now, you can use the Web management interface to continue the Switch management.
  • Page 12: Starting Long Reach Poe Communication

    Note  Connect the Coaxial Cable 1. Insert the coaxial cable with one side being the 75ΩBNC plug connector into the Long Reach Ethernet coaxial interface. 2. Connect the other end of the cable to a device with Long Reach Ethernet coaxial extender installed. 3. Tight the BNC male connector gently. RJ45 5C2V/RG6 75Ω Coaxial Cable Long Reach Power over Ethernet PoE PT Camera LRP-101CE LRP-822CS...
  • Page 13 4. Enable Long Reach Power over Ethernet function for the all LRP ports from WebUI. 5. Check the LNK LED of the Long Reach Power over Ethernet interface on the front of the LRP Managed Switch. Ensure that the Long Reach Power over Ethernet interface is operating correctly.
  • Page 14  Remove the connected the Coaxial Cable 1. Make sure there is no network activity anymore 2. Disable Long Reach Power over Ethernet function for the all LRP ports from WebUI. 3. Loose the BNC male connector gently. 4. Pull out the coaxial cable gently. RJ45 5C2V/RG6 75Ω Coaxial Cable Long Reach Power over Ethernet PoE PT Camera LRP-101CE LRP-822CS...
  • Page 15 Note Switch. 1. The package contains warning stickers, which should be stuck on the coaxial cable connector before using PLANET LRP-822CS / LRP-1622CS and LRP extender. If connected with Non-PLANET LRP series extender equipment, it might cause damage to the equipment.
  • Page 16: Saving Configuration Via The Web

    9. Saving Configuration via the Web In the LRP Managed Switch, the running configuration file stores in the RAM. In the current version, the running configuration sequence of running-config can be saved from the RAM to FLASH by “Save Configurations to FLASH” function, so that the running configuration sequence becomes the startup configuration file, which is called configuration save.
  • Page 17: Recovering Back To Default Configuration

    Console CAUTION The LRP interface is allowed to connect to LRP Extender only. RESET PoE In-Use 115200, N, 8, 1 Figure 10-1: LRP-822CS Reset Button CAUTION The LRP interface is allowed to connect to LRP-1622CS LRP Extender only. Console RESET...
  • Page 18: Customer Support

    PLANET online FAQ: http://www.planet.com.tw/en/support/faq.php?type=1 Switch support team mail address: support_switch@planet.com.tw LRP-822CS / LRP-1622CS User’s Manual: http://www.planet.com.tw/en/support/download.php?type1=1&model=&type=3 (Please select your switch model name from the Product Model drop-down menu) Copyright © PLANET Technology Corp. 2015. Contents are subject to revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners.