Lenovo System x3550 M4 Installation And Service Manual page 498

Hide thumbs Also See for System x3550 M4:
Table of Contents

Advertisement

Alert Category
System - Predicted Failure
SNMP Trap ID
27
CIM Information
Prefix: PLAT ID: 0168
User Response
1. Run the hard disk drive diagnostic test on drive n.
2. Reseat the following components: a. Hard disk drive b. Cable from the system board to the
backplane.
3. Replace the following components one at a time, in the order shown, restarting the server
each time: a. Hard disk drive. b. Cable from the system board to the backplane. c. Hard disk
drive backplane. (n = hard disk drive number)
806f0223-2101ffff : Powering off system [ComputerSystemElementName] initiated by
[WatchdogElementName]. (IPMI Watchdog)
This message is for the use case when an implementation has detected a Poweroff by Watchdog has
occurred.
May also be shown as 806f02232101ffff or 0x806f02232101ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0372
User Response
No action; information only.
• 806f0308-0a01ffff : [PowerSupplyElementName] has lost input. (Power Supply 1)
This message is for the use case when an implementation has detected a Power Supply that has input
that has been lost.
May also be shown as 806f03080a01ffff or 0x806f03080a01ffff
484
System x3550 M4 Installation and Service Guide

Advertisement

Table of Contents
loading

Table of Contents