Figure 154. ServeRAID H1110 adapter cable routing
b.
ServeRAID M1115 adapter: Take the signal cable that is attached to the drive backplane for
drive bays 4 through 7 and connect it to the ServeRAID adapter connector for drive bays 4
through 7 (port 1). Connect the other signal cable that is attached to the drive backplane for
drive bays 0 through 3 and connect it to the other connector (port 0) on the adapter.
Figure 155. ServeRAID M1115 adapter cable routing
c.
ServeRAID M5110 adapter: Take the signal cable that is attached to the drive backplane for
drive bays 4 through 7 and connect it to the ServeRAID adapter connector for drive bays 4
through 7 (port 1). Connect the other signal cable that is attached to the drive backplane for
drive bays 0 through 3 and connect it to the other connector (port 0) on the adapter.
.
Chapter 6
Removing and replacing components
235