Power Supply (For VCR/DVD) & Junction-C Schematic Diagram < VCR Section >
CAUTION !
Fixed voltage ( or Auto voltage selectable ) power supply circuit is used in this unit.
If Main Fuse (F1001) is blown, check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
BECAUSE A HOT CHASSIS GROUND IS PRESENT IN THE POWER
SUPPLY CIRCUIT , AN ISOLATION TRANSFORMER MUST BE USED.
ALSO , IN ORDER TO HAVE THE ABILITY TO INCREASE THE INPUT
SLOWLY , WHEN TROUBLESHOOTING THIS TYPE POWER SUPPLY
CIRCUIT , A VARIABLE ISOLATION TRANSFORMER IS REQUIRED.
1-12-37
10/31/2012
World of free manuals
www.nostatech.nl
CAUTION !
For continued protection against fire hazard,
replace only with the same type fuse.
NOTE :
The voltage for parts in hot circuit is measured
using hot GND as a common terminal.
"
" = SMD
2
PLAY MODE
1
3
5.0
~
5.0
REC MODE
(2.5)
DVD MODE
<5.0>
THE SAME VOLTAGE FOR BOTH
INDICATES THAT THE VOLTAGE
PLAY, REC & DVD MODES.
IS NOT CONSISTENT HERE.
Comparison Chart of
Models and Marks
MODEL
MARK
MX5100VR/00
A
MX5100VR/05
B
MX5100VR/02
C