6. Press "LCH? ? " button on the remote control unit until
the CTL waveform has shifted from its original posi-
tion (not the position achieved in step 5, but the
position of CTL waveform in step 4) by approxi-
mately -2msec. Make sure that the envelope is
simply attenuated (shrinks in height) once CTL
waveform passes its original position and is further
brought in the minus direction.
7. Set the Tracking Control Circuit to the center posi-
tion by pressing "VCR" button and "KCH" button on
the remote control unit then pressing "PLAY" button
on the unit.
1-C. Checking/Adjustment of Envelope
Waveform
Purpose:
To achieve a satisfactory picture and precise tracking.
Symptom of Misalignment:
If the envelope output is poor, noise will appear in the
picture. The tracking will then lose precision and the
playback picture will be distorted by any slight varia-
tion of the Tracking Control Circuit.
1. Connect the oscilloscope to TP301 (C-PB) on the
Main CBA. Use TP504 (RF-SW) as a trigger.
2. Playback the Gray Scale on the Alignment Tape
(FL6NS8). Set the Tracking Control Circuit to the
center position by pressing "VCR" button and
"KCH" button on the remote control unit then
pressing "PLAY" button on the unit.
height of Guide Rollers [2] and [3] (Fig. M3, Page
2-3-3) watching the oscilloscope display so that the
envelope becomes as flat as possible. To do this
adjustment, turn the top of the Guide Roller with
the Guide Roller Adj. Screwdriver.
3. If the envelope is as shown in Fig. M7, adjust the
height of Guide Roller [2] (Refer to Fig. M3) so that
the waveform looks like the one shown in Fig. M9.
4. If the envelope is as shown in Fig. M8, adjust the
height of Guide Roller [3] (Refer to Fig. M3) so that
the waveform looks like the one shown in Fig. M9.
5. When Guide Rollers [2] and [3] (Refer to Fig.M3)
are aligned properly, there is no envelope drop
either at the beginning or end of track as shown in
Fig. M9.
Dropping envelope level at the beginning of track.
10/31/2012
Dropping envelope level at the end of track.
Envelope is adjusted properly. (No envelope drop)
Note: Upon completion of the adjustment of Guide
Rollers [2] and [3] (Refer to Fig. M3), check the X
Value by pushing the "KCH" or "LCH? ? " buttons alter-
nately, to check the symmetry of the envelope. Check
the number of pushes to ensure center position. The
number of pushes "KCH" button to achieve 1/2 level of
envelope should match the number of pushes "LCH? ? "
button from center.
Alignment."
Adjust the
1-D. Azimuth Alignment of Audio/Control/
Erase Head
Purpose:
To correct the Azimuth alignment so that the Audio/
Control/Erase Head meets tape tracks properly.
Symptom of Misalignment:
If the position of the Audio/Control/Erase Head is not
properly aligned, the Audio S/N Ratio or Frequency
Response will be poor.
1. Connect the oscilloscope to the audio output jack
on the rear side of the deck.
2. Playback the alignment tape (FL6NS8) and confirm
that the audio signal output level is 6kHz.
3. Adjust Azimuth Adj. Screw so that the output level
on the AC Voltmeter or the waveform on the oscil-
loscope is at maximum. (Fig. M6)
Fig. M7
2-3-4
World of free manuals
www.nostatech.nl
Fig. M8
Fig. M9
If required, redo the "X Value
E9015MA