Show Console - Panasonic S24GPWR Operation Manual

Hide thumbs Also See for S24GPWR:
Table of Contents

Advertisement

S24GPWR> enable
S24GPWR# configure
S24GPWR(config)# console inactivity-timer 10
S24GPWR(config)# end
S24GPWR# show console
Console UI Idle Timeout: 10 Min.
Console
---------
Active
S24GPWR# configure
S24GPWR(config)# telnet-server inactivity-timer 10
S24GPWR(config)# telnet-server 1 192.168.0.100 255.255.255.255
S24GPWR(config)# telnet-server access-limitation enable
S24GPWR(config)# end
S24GPWR# show telnet-server
Telnet UI Idle Timeout: 10 Min.
Telnet Server
---------------
Enabled
Telnet Access Limitation :
No.
IP Address
---
---------------
1
192.168.0.100
2
<empty>
3
<empty>
4
<empty>
5
<empty>
S24GPWR#
Fig. 3-6 Display of the console and Telnet server configuration
Example: Configuration of user name as mno and password as mno
S24GPWR> enable
S24GPWR# configure
S24GPWR(config)# username mno
Enter old password: *******
Enter new password: ***
Enter new password again: ***
S24GPWR(config)# end
S24GPWR#
Enabled
Subnet Mask
---------------
255.255.255.255
<empty>
<empty>
<empty>
<empty>

(show console)

(show telnet-server)
Fig. 3-8 User name and password configuration
Fig. 3-7
21

Advertisement

Table of Contents
loading

Table of Contents