1. Press the Display button until the Wind Angle
Response page is displayed (1 press from the
User Calibration Access Menu page).
Disp
lay
2. Use the VMG and Tack buttons to set the
required level for Wind Angle Response.
The default level is 12. The levels available are 1
to 15 with level 1 being the slowest update rate
and level 15 the quickest.
Note: To exit the Dealer Calibration pages at any
time, press and hold the Display and True/App
buttons at the same time for approximately 2
seconds.
Setting the response delay for Wind Speed
readings
From the User Calibration Menu Access page:
1. Press the Display button until the Wind Speed
Response page is displayed (2 presses from the
User Calibration Access Menu page).
Disp
lay
2. Use the VMG and Tack buttons to set the
required level for Wind Speed Response.
The default level is 12. The levels available are 1
to 15 with level 1 being the slowest update rate
and level 15 the quickest.
Note: To exit the Dealer Calibration pages at any
time, press and hold the Display and True/App
buttons at the same time for approximately 2
seconds.
Setting the response delay for VMG readings
From the User Calibration Menu Access page:
1. Press the Speed button until the VMG Response
page is displayed (3 presses from User
Calibration Menu Access page).
Disp
lay
2. Use the VMG or Tack buttons to set the required
level for VMG response.
The default level is 12. The levels available are 1
to 15 with level 1 being the slowest update rate
and level 15 the quickest.
Note: To exit the Dealer Calibration pages at any
time, press and hold the Display and True/App
buttons at the same time for approximately 2
seconds.
40
CAL
D12495-2
CAL
D12496-2
CAL VM G
D12497-2
Setting the wind speed Calibration Factor
If you find that your wind speed readings deviate from
a referenced wind speed source then a Calibration
Factor can be applied to reduce the deviation.
From the User Calibration Menu Access page:
1. Press the Display button until the Current Wind
Speed page is displayed (4 presses from the
User Calibration Menu Access page).
Disp
lay
2. Use the VMG and Tack buttons to adjust the
Calibration Factor to the desired value.
When the VMG and TACK buttons are not
being pressed the screen will revert back to
Current Wind Speed page to enable you to see
what change the Calibration Factor has on the
display's Wind Speed reading.
Note: To exit the dealer calibration pages at any
time press and hold the Display and True / App
buttons at the same time for approximately 2
seconds.
Enabling and disabling Boat Show Mode - i60
From the User Calibration Menu Access page:
1. Press the Display button until the Boat Show
Mode page is displayed (5 presses from theUser
Calibration Menu Access page).
Disp
lay
2. Use the VMG or Tack buttons to switch the Boat
Show Mode On and Off (default).
Selecting On will put the display into boat show
mode.
Note: Boat show mode is only suitable for
demonstration purposes and should NOT be used
whilst your vessel is in use.
Note: To exit the dealer calibration pages at any
time press and hold the Display and True / App
buttons at the same time for approximately 2
seconds.
Resetting the display to factory defaults - i60
From the User Calibration Menu Access page:
1. Press the Display button until the Factory Reset
page is displayed (5 presses from the User
Calibration Menu Access page).
Disp
lay
2. To reset the display to factory default settings:
i. Use the VMG or Tack buttons to change the
reset option to F 1 (default).
ii. Press the Display button to reset your display
to factory default settings.