Gun Operation Troubleshooting

PROBLEM
Leakage from fluid needle area
Air leakage from front of gun
Fluid leakage from front of gun
"Orange Peel" finish
Excessive spray fog
No fluid sprays from gun
Equipment covered with fluid
Paint build-up on air cap
Fluid doesn't shut off properly
Air leakage from manifold
* Use the least air/fluid pressure needed for good results.
26
308387
Troubleshooting
CAUSE
Fluid needle packings loose
Fluid needle packing damaged
Piston air valve not seating properly
Fluid needle worn
Fluid seat loose or worn
Spray tip loose
Tip seal damaged
Atomization air pressure too low
Fluid pressure too low
Spray tip too large
Fluid poorly mixed or filtered
Improper thinner being used
Atomization air pressure too high
Fluid thinned too much
Fluid supply low
Cylinder air pressure too low
Spray tip dirty or clogged
Spray tip damaged
Actuator arm not adjusted properly
Piston sticking
Fluid needle damaged
Booth exhaust air flow too low or not
directed properly
Improper distance between gun and
workpiece
Gun shroud loose or o-ring (9) missing
Atomization air pressure too high
Air cap dirty
Seat housing over-tightened
Fluid leakage buildup on fluid needle
Fluid packings too tight
Piston sticking
Manifold not tight
Worn or missing o-rings
SOLUTION
Tighten packing nut; See page 37
Replace fluid needle; See page 37
Clean, Service; See page 35
Replace fluid needle; See page 37
Tighten or replace fluid seat
Tighten retaining nut
Replace tip seal; See page 32
Increase atomization air pressure*
Increase fluid pressure with gun fluid regulator*
Use a smaller size spray tip; See page 49
Remix or refilter fluid
Use proper thinner
Reduce atomization air pressure*
Properly thin fluid
Check; Add fluid if necessary
Increase cylinder air pressure; 50 psi (3.5
bar, 0.25 MPa) minimum required
Clean spray tip; See page 22
Check; Replace spray tip; See page 32
Adjust the actuator arm; See page 35
Service piston o-rings; See page 35
Replace fluid needle; See page 37
Check for proper CFM; Check baffles and
direction of air flow
Adjust spraying distance to 8 to 12 inches
(203 to 305 mm)
Tighten retaining nut (1); Check o-ring (9);
See page 42
Reduce atomization air pressure*
Clean air cap; See page 22
Replace seat housing; See page 32
Replace fluid needle; See page 37
Adjust fluid packings; See page 37
Service piston o-rings; See page 35
Tighten manifold screws; See page 41
Inspect or replace o-rings (items 5 and 118);
see pages 42 and 44