Troubleshooting

Malfunction
Cause
í Light does not switch ON
í No supply voltage
í Lux value set too low
í No motion detection
í Light does not switch OFF
í Lux value too high
í Overshoot time running out
í Interferring sources of
heat, e.g.: fan heaters,
open doors and windows,
pets
í Sensor switches OFF
í Overshoot time too short
in spite of occupancy
í Sensor switches OFF
í Overshoot time too long
too late
í Sensor switches ON too
í Reach is reduced when
late when approached
approached frontally
frontally
í Sensor switches
í Overshoot time set too
too frequently with chang-
short
ing cloud cover
only BLS D, DF:
í Sensor does not react to
í Control leads (+,–)
changes in brightness in
not correctly wired
test mode
only BLS DF:
í Sensor does not switch ON
í Sensor previously switched
with occupancy in spite of
OFF with hand-held trans-
darkness
mitter
í Lux value selected too low
í The light level set with the
í Settings deleted, since
hand-held transmitter is no
voltage supply to the sen-
longer saved
sor cut off
(e.g. by light switch or
power failure)
20
Remedy
í Check supply voltage
í Slowly increase lux value
until light switches ON
í Establish a clear view of
the sensor
í Check detection zone
í Reduce lux value
í Wait until overshoot time
elapses; reduce overshoot
time if necessary
í Blank off stationary
sources of interference
using shrouds
í Increase overshoot time
í Reduce overshoot time
í Install further sensors
í Reduce distance between
two sensors
í Increase overshoot time
more pleasant switching
behaviour
í Replace the control leads
on the sensor or electronic
ballast
í Activate sensor by press-
ing the (+) button on the
hand-held transmitter
í Increase lux value on the
sensor or by pressing the
(+ ) button on the hand-
held transmitter
í Ensure voltage supply to
the sensor
PK Elektronik Vertriebs GmbH, E-Mail: info@pkelektronik.com, Internet: www.pkelektronik.com

Declaration of conformity

This product complies with
04/108/EC and RoHS
Low Voltage Directive
Directive 02/95/EC.
06/95/EC, EMC Directive
Functional Warranty
This Steinel product has been
The warranty period is 36
manufactured with utmost
months and starts on the date
care, tested for proper opera-
of sale to the consumer. We
tion and safety and then sub-
will remedy defects caused by
jected to random sample in-
material flaws or manufactur-
spection. STEINEL undertakes
ing faults. The warranty will be
the guarantee for perfect con-
met by repair or replacement
dition and function.
of defective parts at our own
discretion. The warranty shall
not cover damage to wear
parts, damage or defects
caused by improper treatment
or maintenance. Further con-
sequential damage to other
objects is excluded.
Claims under the warranty
shall only be accepted if the
product is sent fully assem-
bled and well packed com-
plete with a brief description of
the fault, a receipt or invoice
(date of purchase and dealer's
stamp) to the appropriate Ser-
vice Centre.
Repair Service:
Our Customer Service Depart-
ment will repair faults not cov-
ered by warranty or after the
warranty period. Please send
the product well packed to
your nearest Service Centre.
21

Advertisement

Table of Contents
loading

Table of Contents