9.
Flush until approximately 1/3 of the
flushing fluid is emptied from the hop-
per.
10. Turn ON/OFF switch to OFF position.
NOTE: Step 11 is for returning paint in hose
to paint pail. One 50 ft (15 m) hose holds
approximately 1 quart (1 liter) of paint.
11. To recover paint in hose:
a.
Point gun into paint pail.
b.
Disengage trigger lock.
c.
Pull and hold gun trigger.
d.
Place Prime/Spray valve in SPRAY
position.
e.
Turn ON/OFF switch to ON position.
f.
Continue to hold gun trigger until
you see paint diluted with flushing
fluid starting to come out of gun.
12. While continuing to trigger gun, quickly
move gun to redirect spray into waste
pail. Continue triggering gun into waste
pail until flushing fluid dispensed from
gun is relatively clear.
ti27151a
13. Stop triggering gun. Engage the trigger
lock.
3A3212C
14. Place Prime/Spray valve in PRIME
position.
ti27264a
15. Turn ON/OFF switch to OFF position.
16. On sprayers with a filter, see Cleaning
InstaClean
17. Fill unit with Pump Armor
fluid. See Storage, page 29.
Cleanup
™
Fluid Filter, page 28.
™
storage
ti24931a
ti27263a
27