Safety considerations

Installation and servicing of air conditioning equipment can
be hazardous due to system pressure and electrical
components.
Only trained and qualified service personnel should install,
repair or service air conditioning equipment.
All maintenance operations must be carried out by skilled
personnel.
When working on air conditioning equipment, observe
precautions on the literature, tags and labels attached to the
unit and other safety precautions that may apply.
Follow all safety codes.
Wear safety glasses and workgloves.
Use a quenching cloth for unbrazing operations.
WARNING:
Before performing service or maintenance operations turn off
the main power switch to unit.
Electrical discharge could cause personal injury.
The 40SMC---N unit is designed for installation with ducts.
If this is not the case, the installer must place a protection
mesh in the discharge according to the standards in force.
This unit is not suitable for use in laundry premises.
Table I: Phisical data
40SMC---N
Weight
Indoor coil
Material
Quantity
Front surface
Fins per inch
Nº rows -tube diameter
Fan motor
Quantity
Electrical capacitor
Nom. power (1)
Nom. cons. (1)
Fan
Quantity
Diameter - lenght
Refrigerant
Type
Control
Approx. charge (2)
Air filter
Quantity
DImensions
NOTES:
(1) Motor on high speed.
(2) Refrigerant charge depends on the outdoor unit to be connected.
(3) The restrictor is located into the outdoor unit.
Table II - Electrical data (cooling only) - 38GL(S) - 38BC(S) + 40SMC---N
38GL(S) - 38BC(S)
+
40SMC---N
Operation voltage
CONSUMPTION
Nominal *
Máximum **
On short circuit
NOTES:
*
Outdoor dry bulb temperature = 35
**
Outdoor dry bulb temperature = 43
Outdoor unit operation voltage
Outdoor unit operation voltage
GB - 2
009
012
22
22
Aluminium/Copper
1
1
m
2
0,145
0,145
14
14
2...3/8"
2...3/8"
1
1
µF
4
5
W
80
90
Amp
0,36
0,40
2
2
mm
146x176
146x176
R-410A
R-410A
Restrictor (3) Restrictor (3) Restrictor (3) Restrictor (3) Restrictor (3) Restrictor (3) Restrictor (3) Restrictor(3)
Kg
See note
See note
Washable
Washable
1
1
mm
685x218
685x218
09
12
+
+
009
012
V/Ph/Hz
kW
1,03
1,23
Amp
4,56
5,45
kW
1,23
1,47
Amp
5,56
6,65
Amp
28,5
35,0
o
C; Indoor wet bulb temperature = 19
o
C; Indoor wet bulb temperature = 23
230V ~ 50Hz
400V 3N~ 50Hz
Only use original spare parts when repairing and pay special
attention when positioning the same.
They must be placed indentically to the previus ones.
These units must not be installed in an explosive
atmosphere.
These units must not be installed in an explosive
atmosphere.
The units con operate in residential, commercial and light
industrial installations which have normal radioelectrical
atmospheres consultation must be made for other applications.
WARNING:
This unit base can incorporate a drain pan.
Do not drill through base or damage to drain pan and
refrigerant circuit may result.
The air must be filtered before entering the evaporator, or the
guarantee becomes invalid. Do not use undue force or
excessive manipulation of the refrigerant connections and
pipes.Ensure that no piping touches any adjacent part.
If necessary, adjust carefullly because the guarantee does not
cover leaks due to a negligent handling of the pipes. Split
units can contain a maintenance charge. Purge before de-
soldering the plugs.
018
024
22
36
1
1
0,145
0,245
14
14
3...3/8"
2...3/8"
1
1
4,5
5,5
100
190
0,45
0,85
2
2
146x176
185x240
R-410A
R-410A
See note
See note
Washable
Washable
1
1
685x218
684x283
18
24
+
+
018
024
1,82
2,26
8,23
10,20
12,67/4,22
2,18
2,71
9,86
12,30
15,20/5,06
51,5
78,0
84,5/47,5
o
C.
o
C.
028
036
048
36
36
60
1
1
1
0,245
0,245
0,400
12
14
12
3...3/8"
3...3/8"
3...3/8"
1
1
1
6,3
8
6
220
305
420
1,0
1,35
1,90
2
2
2
185x240
185x240
200x240
R-410A
R-410A
R-410A
See note
See note
See note
Washable
Washable
Washable
1
1
1
684x283
684x283
1172x308
28
36
48
+
+
+
028
036
048
/
/
/
2,80
3,53
4,05
16,0/5,32
13,6/7,80
3,36
4,23
4,50
19,15/6,37
15,07/8,67
108,0/49,0
103,0/53,0
060
60
1
0,400
14
3...3/8"
1
8
560
2,50
2
200x240
R-410A
See note
Washable
1
1172x308
60
+
060
5,20
18,6/10,7
6,60
23,6/13,6
124,0/64,0