Table(cont.)
Item
Type
Capacity
Dehumidifying
Air Volume
Perfor-
Noise
mance
Energy Efficiency Ratio Heating
Power
Power Consumption
Operating Current
Power
Power Factor
Starting Current
Power Cord
Outer Dimension
Weight
Refrigerant Pipe
Size
Drain Hose
Type
Compressor
Motor
Type
Blower
Motor
Heat Exchanger
Refrigerant Control Unit
Freezer Oil Capacity
Refrigerant to Change(R22)
Protection Device(OLP)
Cooling Test Condition
Maximum Operation Condition
4
Model
Cooling
Heating
BTU/h
SASO
|/h
m
3
/min
dB
Cooling
BTU/W . h
SASO
V-Hz
Cooling
Heating
W
SASO
Cooling
Heating
A
SASO
Cooling
Heating
%
SASO
A
Length
m
Number of Core Wire
Capacity
A
mm
890x285x179
W x H x D
inch
35.0x11.2x7.0
kg
Liquid
mm x L(m)
GAS
mm x L(m)
D x L(mm)
Type
Rated Output
Type
Rated Output
W
2ROW 12STEP
cc
g
AQT12P4GB
Indoor unit
Outdoor unit
Wall-mounted
12,000
13,000
10,500
1.9
8.2
2.4
43
53
10.0
10.5
7.44
1-220-60
1,200
1,240
1,410
5.5
5.7
6.5
99.2
98.9
98.6
32.0
-
-
250V-10/16A
720x530x260
28.3x20.9x10.2
8.5
33.0
ø6.35 x 5
ø12.7 x 5
ø18 x 2,000
Rotary
-
-
-
-
Cross-Flow
Propeller
steel
steel
15
25
2ROW 24STEP
CAPILLARY TUBE
600
960
RBC12107-12500
INDOOR UNIT : DB27˚C WB19˚C
INDOOR UNIT : DB32˚C WB23˚C
AQT12P4GE
Indoor unit
Outdoor unit
Wall-mounted
12,000
13,000
-
1.9
8.2
2.4
43
53
10.0
11.0
-
1-220 /240-50
1,200
1,180
-
5.3
5.2
-
98.4
98.7
-
32.0
-
-
250V-10/16A
890x285x179
720x530x260
35.0x11.2x7.0
28.3x20.9x10.2
8.5
33.0
ø6.35 x 5
ø12.7 x 5
ø18 x 2,000
Rotary
-
-
-
-
Cross-Flow
Propeller
steel
steel
15
25
2ROW 12STEP
2ROW 24STEP
CAPILLARY TUBE
410
940
RBC12050-12500
OUTDOOR UNIT : DB35˚C WB24˚C
OUTDOOR UNIT : DB43˚C WB26˚C
Samsung Electronics