ROOM AIR CONDITIONER INDOOR UNIT OUTDOOR UNIT SH07AS2 SH07AS2X SH07AS2A SH07AS2AX SH09AS2 SH09AS2X SH12AS4 SH12AS4X Manual SERVICE AIR CONDITIONER CONTENTS 11. Product Specifications 12. Operating Instructions 13. Disassembly and Reassembly 14. Refrigerating Cycle Diagram 15. Set Up the Model Option 16.
1. Product Specifications 1-1 Table Model SH07AS2 SH07AS2A Item Indoor unit Outdoor unit Indoor unit Outdoor unit Type Wall-mounted Wall-mounted Cooling 2.30 2.30 Heating 2.40 2.40 Dehumidifying Cooling Air Volume /min Perfor- Heating mance Noise Cooling 2.95 2.95 Energy Efficiency Ratio Heating 3.24...
Page 3
CAPILLARY TUBE Freezer Oil Capacity Refrigerant to Change(R410A) Protection Device(OLP) RBC12131-12500 RBC12128-12500 INDOOR UNIT : DB27˚C WB19˚C OUTDOOR UNIT : DB35˚C WB24˚C Cooling Test Condition Maximum Operation Condition INDOOR UNIT : DB32˚C WB23˚C OUTDOOR UNIT : DB43˚C WB26˚C Samsung Electronics...
30 minutes to 24 hours. To cancel, press the (Set/Cancel) button. Energy Saving button. If you wish to save energy when using your air conditioner, select the Energy saving mode with the button. Samsung Electronics...
Page 6
Room Temperature Operating Mode Temperature Setting heat exchanger temperature and accumulating time of Less than 21˚C Heat 22˚C approx. compressor's operation. Deice ends by sensing of the processing time by deice 21˚C or above Cool 24˚C approx. condition. Samsung Electronics...
Page 7
: Lamp off : Lamp flickering 12. BUZZER SOUND : Whenever the On/Off button is pressed or whenever change occurs to the condition which is set up or select, the compulsory operation mode, buzzer is sounded "beep". Samsung Electronics...
2-2 Replace PCB Model option 2-2-1 Replace PCB model option Remove power cord Replace the PCB module Check the connection and plug in Replace another PCB Does all display lamp blink? Refer to set up the Model option(14~16page) Samsung Electronics...
And press the right of the upper side of the Panel Grille with the fingers. And then disassemble the Panel Grille. 10) Pull the lower left and right of discharge softly for the outside cover to be pulled out. Samsung Electronics...
Page 10
1) Loosen 2 fixing earth screws of right side. Heat Exchanger 2) Detach the Connection Pipe. 3) Detach the Holder Pipe at the rear side. 4) Loosen 3 fixing screws of right and left side. 5) Detach the Heat Exchanger from the indoor unit. Samsung Electronics...
Page 11
1) Loosen 2 fixing screws and detach the Fan Motor Motor Holder. & 2) Loosen 1 screw of Fan Motor. Cross Fan (By use of M3 wrench) 3) Detach the Fan Motor from the Fan. 4) Detach the Fan from the left Holder Bearing. Samsung Electronics...
Page 12
2) Loosen 1 fixing screw and detach the Cover Control. 3) Detach the connection wire from the Terminal Block. 4) Loosen 13 fixing screws and detach the Cabinet-Front. 5) Loosen 1 fixing screw of Ass'y E-part. 6) Loosen 4 fixing screws and detach the Cabinet-Side. Samsung Electronics...
Page 13
3) Detach the Heat Exchanger. Compressor 1) Open the Terminal Cover of Compressor and unscrew the Connection Terminal. 2) Disassemble the inlet and outlet pipe of Compressor by welding. 3) Loosen 3 bolts of the lower part. 4) Detach the Compressor. Samsung Electronics...
4. Refrigerating Cycle Diagram Outdoor Unit Indoor Unit Capillary tube 2-Way valve Liquid side Heat Heat Exchanger Exchanger (Evaporator) (Evaporator) Gas side 3-Way valve 4-Way valve Cooling Heating Compressor Gas leak check point Samsung Electronics...
. . . repeatedly. Setting is not required if you must a value which has a default. Push the button to set the display panel to Every time you push the button, the display panel reads . . . repeatedly. Samsung Electronics...
Page 16
If all lamps of indoor unit are flickering, Plug out and plug in battery again and pressing ON/OFF key to retry. If the unit is not working properly or all lamps are continuously flickering after setting the option code, see if the correct option code is set up for it's model. Samsung Electronics...
Page 17
Set Up the Model Option OPTION ITEMS REMOCON SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 MODEL SH07AS2 SH07AS2A SH09AS2 SH12AS4 Samsung Electronics...
The compressor operates in a reverse cycle to remove exterior ice in a HEAT mode, and indoor fan and outdoor fan Indoor fan and outdoor fan stop operation intermittently in a HEAT mode. do not operate intermittently for within 20% of the total heater operation Samsung Electronics...
Page 19
Problem with the outdoor unit or PCB outdoor unit remote control. • In 3 minutes, check the voltage No power source Problem with the relay (RY71) or PCB between the indoor unit terminal displayed. block N(1) and 1. Samsung Electronics...
Check whether the fuse on the Replace fuse control board is normal. FUSE: 3.15[A]/250[V] Check the output of SMPS on the control board. Input power: AC230±15%[V] PCB should be replaced IC02 Input: DC 12[V] IC02 output: DC 5[V] Check the setting temperature Samsung Electronics...
SENSOR Resistance Value : 40˚C-5.83kΩ Connect the sensor to CN43, supply power, and measure the voltage of #1 and #2 of the CN43 connector. Poor ASS'Y PCB Replace Below 0.5V? Poor ASS'Y PCB Replace Over 4.9V? MICOM Error or Connector(CN43) check Samsung Electronics...
Page 22
3. Assemble the room pipe sensor to PCB, plug in, and check the voltage of connector 3 and 4. If the resistance is below 0.5V or over 4.9V, replace the indoor Main PCB. (short or disconnected in the PCB board) Samsung Electronics...
Test rod location Normal voltage PCB CN72 Condition pin #3 and #5 Fan operating About AC 180V Replace Motor Motor Fan-Capacitor is out of order Fan-Capacitor Fan motor should be replaced. Fan motor is out of order. Samsung Electronics...
Power relay is Is rating voltage ±10% range applied relay between replaced. out of order Terminal block No. N(1) and No. 1 Outdoor unit is out of order. Is the room sensor normal resistor? 10°C 20°C 30°C 17.96kΩ 12.09kΩ 8.3kΩ Samsung Electronics...
Page 25
Abnormal IC05 Is the voltage between CN71 #1 and CN71 #5 rating voltage ±10% range Abnormal RY73 Abnormal 4-Way valve of Outdoor Unit. or connecting Cable PCB should be replaced. 4-Way valve should be replaced or connecting Cable Check. Samsung Electronics...
Page 26
When the voltage descends below 3V, the assembly module PCB is normal and the main PCB is poor. Then replace the main PCB. 3. Replace the assembly display PCB because the module PCB is poor if the voltage between No. 2~3 of CN91 maintains 5V after the remote control starts operation. Samsung Electronics...
7. Exploded Views and Parts List 7-1 Indoor Unit 14-1 14-6 14-2 14-4 14-3 14-5 You can search for the updated part code number through the ITSELF. URL : http://itself.sec.samsung.co.kr Samsung Electronics...
Page 28
Exploded Views and Parts List Parts List Q'TY Code No. Description Specification Remark SH07AS2 SH09AS2 SH12AS4 SH07AS2A DB92-00574A ASS'Y PANEL FRONT TOTAL ASS'Y DB92-00582A ASS'Y PANEL FRONT TOTAL ASS'Y DB92-00575A ASS'Y PANEL FRONT SVC ASS'Y DB92-00581A ASS'Y PANEL FRONT SVC...
• STEPPING MOTOR DRIVE (H/M/L) PART • BUZZER DRIVE • FUNCTION DRIVE* BLADE-H STEPPING MOTOR MOVING SELECT -Blade -Auto grille* ON, OFF TIMER SELECT DC 5V TEMPERATURE SELECT VOLTAGE REGULATOR SLEEP SELECT DC 12V SMPS Power Block FUNCTION* SELECT AC INPUT Samsung Electronics...
10. Wiring Diagram 10-1 Indoor Unit(7K/9K/12K) Code No : DB98-15135A This Document can not be used without Samsung's authorization. Samsung Electronics...
Page 42
10-2 Outdoor Unit MOTOR CAPACITOR FAN MOTOR COMP CAPACITOR O.L.P OVER LOAD PROTECTOR Code No : DB98-15123A This Document can not be used without Samsung's authorization. Samsung Electronics...