9.
SWING : BLADE-H is rotated vertically by the stepping
motor.
*Swing Set : Press the
control is displayed on LCD the
move up and down. If the one more time press the
button, blades location is stop.
10. SETTING THE ON/OFF TIMER. :
*ON TIMER : The On Timer enables you to switch on the
air conditioner automatically after a given period of time.
You can set the period of time from 30 minutes to 24
hours.
*OFF TIMER : The Off Timer enables you to switch off
the air conditioner automatically after a given period of
time. You can set the period of time from 30 minutes to
24 hours.
11. GENERATING ANION :
The air conditioner can generate anion with an ionizer in
the indoor unit.
Samsung Electronics
button under the remote
and the blades
12. SELF DIAGNOSIS
Error Mode
Indoor unit room temperature sensor
error (open or short)
Indoor unit heat exchanger
temperature sensor error(open or short)
Indoor FAN MOTOR error :
Keep the RPM value 450 below for
15 seconds
EEPROM error
Error in option
In case of No option set-up
In case of option data error
13. BUZZER SOUND : Whenever the On/Off button is
pressed or whenever change occurs to the condition
which is set up or select, the compulsory operation mode,
buzzer is sounded "beep".
Operating Instructions
DISPLAY 7-SEGMENT
Remark
Operation Off Operation On
OFF
E1
OFF
E2
OFF
E3
OFF
E6
All lamp
All lamp
blinking
blinking
9