Download Print this page

Configuration Menu; Technical Specifications; System Mode; Fan Mode - Aube Technologies TH149 Installation And User Manual

Aube technologies electric thermostat for heat pump and hvac systems

Advertisement

Configuration Menu

The configuration parameters appear in the order shown below.
PARAMETERS
DEFAULT
Temperature display
1
Heating cycles per hour
1
Cooling cycles per hour
System type
3
1H1C type
1
When either the heating or the cooling parameter is displayed, use the
mode selector switch to toggle between the two parameters.
2
The corresponding cycle lengths are: 2 = 30 min., 3 = 20 min.,
4 = 15 min., 5 = 12 min., 6 = 10 min.
3
This parameter appears only if you select 1H1C for the system type.
To access the configuration menu, press and hold both temperature
adjustment buttons for more than 3 seconds.
To go to the next parameter, once in the menu, press both temperature
adjustment buttons for more than 2 seconds.
To modify the displayed parameter, press one of the temperature adjust-
ment buttons.
You will exit the configuration menu at the end of the menu.
Note:
The settings are not erased during a power outage.
Operation

4.1 System Mode

Use the system mode selector switch to place the system in heat
mode, cool mode, emergency heat (E.H.) mode, or off.
Note:
Emergency heat mode is not available on 1H1C systems.
For these systems, placing the selector on E.H. is the same as
placing it on Off.
Auxiliary Heat
Only 2H1C systems are equipped with auxiliary heat. The auxiliary heat is
used in the following conditions:
• When the setpoint is not attained after a 15-minute delay following the
compressor activation. After the delay, the auxiliary heating is used along
with the compressor.
• When the thermostat is placed in emergency heating (E.H.). In this mode,
only the auxiliary heat is used.

4.2 Fan Mode

Use the fan mode selector switch to place the fan in automatic
mode (AUTO) or continuous mode (ON).
Note:
This switch is not functional if the fan is not connected to
the thermostat.
AUTO
The fan operates only when heating or cooling is activated.
ON
The fan operates continuously.
4.3 Viewing and Setting the Temperature
The actual temperature is normally displayed. To view the setpoint, press
once on one of the temperature adjustment buttons. The setpoint is displayed
for 5 seconds and is indicated by the
press the appropriate temperature adjustment button during the setpoint dis-
play.
4.4 Backlight
The display illuminates for 12 seconds when either of the temperature adjust-
ment buttons is pressed.
TH149
OPTIONS
°C
°C or °F
4
2, 3, 4, 5 or 6
4
2, 3, 4, 5 or 6
2H
2H (2H1C) or 1H (1H1C)
HP
HP (Heat Pump) or Cn (HVAC)
icon display. To change the setpoint,
4.5 Setpoint Lock
3.
A switch on the back of the front module can be used to lock the setpoint.
Remove the front module from the
back plate to access the switch.
Place the switch (S1) to the I posi-
2
tion.
2
Reinstall the front module.

Technical Specifications

Power supply: 24 VAC
Maximum load: 1.5 A per output @ 24 VAC
Setpoint range (heat): 5 to 28°C (41 to 82°F)
Setpoint range (cool): 15 to 35°C (59 to 95°F)
Setpoint increment: ± 0.5°C (1°F)
Display range: -5 to 50°C (23 to 122°F)
Display resolution: 0.5°C (1°F)
Short-cycle protection: 2 minutes
Storage temperature: -20 to 50°C (-2 to 122°F)
Dimensions: 79 mm x 81 mm x 25 mm (3.1 in. x 3.2 in. x 1.0 in.)
Warranty
Aube warrants this product, excluding battery, to be free from defects in the
workmanship or materials, under normal use and service, for a period of three (3)
years from the date of purchase by the consumer. If at any time during the warranty
4.
period the product is determined to be defective or malfunctions, Aube shall repair
or replace it (at Aube's option).
If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to the place from
which you purchased it, or
(ii) contact Aube. Aube will make the determination whether the product should be
returned, or whether a replacement product can be sent to you.
This warranty does not cover removal or reinstallation costs. This warranty shall
not apply if it is shown by Aube that the defect or malfunction was caused by
damage which occurred while the product was in the possession of a consumer.
Aube's sole responsibility shall be to repair or replace the product within the terms
stated above. AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF
ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES
RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY
WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS
PRODUCT. Some provinces and states do not allow the exclusion or limitation of
incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS
PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS
WARRANTY. Some provinces and states do not allow limitations on how long an
implied warranty lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which
vary by province, state or region.

Technical Support

For any questions regarding product installation or operation, contact our
technical support team at:
705, Montrichard
Saint-Jean-sur-Richelieu, Quebec
J2X 5K8
Canada
Tel.: (450) 358-4600
Toll-free: 1-800-831-AUBE
Fax: (450) 358-4650
Email: service@aubetech.com
For more information on our products, visit us at
www.aubetech.com
400-149-000-B
5.
6.
7.
10/5/05
2/2

Advertisement

loading