Operation; Maintenance - Dimplex CKHA Series Instructions Manual

Kickspace heater
Hide thumbs Also See for CKHA Series:
Table of Contents

Advertisement

Available languages

Available languages

Soffit or Stair Riser Installation
1.
Cut opening as for kickspace installation (22 3/8" x 3
5/8"). Allow 3/4" clearance above cabinet doors. Add
supports for unit (Figure 3).
2.
Proceed as for kickspace installation. After securing unit
in opening, install combination of frame and grille (Figure
1).
FIGuRE 3
CEILING
GRILLE
HEATER
CABINET
DOOR
Fi�ure 4
FACtoRY ConnECtIon
208/240 VoLt 675/900 WAttS
3�2 A / 3�7A
FAN
M
ImpoRtAnt: RETIGHTEN ALL LEADS WITH CABLE CLAMP AFTER RECONNECTING
UNINSULATED ENDS OF UNUSED LEADS WITH WIRE NUTS
notE: If installing unit with factory thermostat, see supplemental wiring diagram, Fig. 4a.
2
3/4
MIN.
PARTITION OR
ADDED SUPPORT
FACtoRY ConnECtIon
208/240 VoLt 1350/1800 WAttS
6�5 A / 7�5 A
FAN
M
SAFETY SWITCH

operation

1.
This heater must be properly installed before it is used.
2.
Prior to energization remove all construction dirt (plaster,
sawdust, etc.) from interior and exterior of heater.
3.
Adjust thermostat with screwdriver. This unit is also
controllable from a line voltage wall thermostat or field
installed built-in tamperproof single or double pole
thermostat kit.
Dimplex kickspace heaters are designed and tested for safe
and trouble-free operation. All Dimplex kickspace heaters
are protected against overheating by a built-in thermal cutout.
Free airflow throughout the heater is extremely important for
the most efficient operation of the heater. Restricted airflow
may cause the thermal overload protector to cycle the heater
"ON and OFF". A cycling heater will not supply sufficient heat
to the room.
Avoid direct contact of paper, fabric, or furniture with heater.

maintenance

CAutIon: Disconnect all power coming to heater at
main service panel before wiring or servicing.
SERVICInG - Remove grille and frame by removing screws
"A". Remove two screws "B", and slide out heating assem-
bly. When re-assembling, reverse the procedure above.
Cleanin�
With �rille in place
out lint and dirt around grille. Reverse hose on vacuum
to use as a blower to move dust out of enclosure. Re-
verse hose back to suck out dirt at front area of heater.
With �rille removed
front of heating element assembly. Pull gently to remove
it from enclosure. Swing assembly out. Vacuum inside
of enclosure and around heating element assembly. Re-
verse procedure above to re-assemble unit.
FACtoRY ConnECtIon
120 VoLt
FAN
SAFETY SWITCH
- Use vacuum cleaner hose to suck
- Remove two screws "B" at bottom
M
SAFETY SWITCH
RAtInG
ConnECt
450W/ 3.75A
7-8 (AS SHOWN)
900W/ 7.5A
7-8, 1-2
1350W/ 11.2A
7-8, 1-2, 3-4
1800W/ 15A
7-8, 1-2, 3-4, 5-6
Fi�ure 4a
THERMOSTAT
www.dimplex.com

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rkha series

Table of Contents