8.3

Virtual Masks

Virtual masks allow users to mask parts of the scene which should not be considered for flow
analysis to trigger Intelligent Tracking. This allows users to mask background motion in the
scene such as moving trees, pulsating lights, busy roads, etc.
To create a virtual mask:
1. Select the number of the Virtual mask. In the video preview window, a dark grey rectangle
appears with the text "Mask x," where 'x' is the number of the mask.
2. Select the mask with your mouse. Move the mouse to position the mask over the area of the
view that you want to mask, and then click "Set." The text "VM Configuration active!" appears
in the View Control window.
3. Click Enabled to enable the virtual mask. The rectangle that represents the mask in the
preview window becomes red. The text "Virtual Masks: ENABLED" appears in the View Control
window.
To disable virtual masks:
Click the Disable masks checkbox. The text "Virtual Masks: DISABLED" appears in the View
Control window.
8.4

Audio Alarm

Note for MIC7000 cameras only: These options are available only if you have connected a
VIDEOJET connect device (VJC-7000-90) to your camera.
The camera can create alarms on the basis of audio signals. You can configure signal strengths
and frequency ranges in such a way that false alarms, for example due to machine noise or
background noise, are avoided.
Notice!
First set up normal audio transmission before you configure the audio alarm here (see Audio).
Audio alarm
Select On if you want the device to generate audio alarms.
Do not use any special characters, for example &, in the name. Special characters are not
supported by the system's internal management.
Signal Ranges
You can exclude particular signal ranges in order to avoid false alarms. For this reason the
total signal is divided into 13 tonal ranges (mel scale). Check or uncheck the boxes below the
graphic to include or exclude individual ranges.
Threshold
Set up the threshold on the basis of the signal visible in the graphic. You can set the threshold
using the slide control or, alternately, you can move the white line directly in the graphic using
the mouse.
Sensitivity
You can use this setting to adapt the sensitivity to the sound environment. You can effectively
suppress individual signal peaks. A high value represents a high level of sensitivity.
8.5

Alarm E-Mail

As an alternative to automatic connecting, alarm states can also be documented by e-mail. In
this way it is possible to notify a recipient who does not have a video receiver. In this case, the
camera automatically sends an e-mail to a previously defined e-mail address.