Kodak i1800 SERIES User Maintenance Manual page 28

Hide thumbs Also See for i1800 SERIES:
Table of Contents

Advertisement

Messages
Input elevator too full, feed module
missing or broken
Invalid job setup
Jam in transport
Lamps not ready for calibration
Lamps not ready for scanning
Lamps ready for calibration
Lamps ready for scanning
Lamps timed out
No paper input elevator
A-61555 May 2010
ID#
297
• There is too much paper in the input elevator and it is holding
the feed module up. The maximum input elevator capacity is
500 sheets. Remove some documents from the input elevator.
• The feed module is not installed properly. See Chapter 5,
Maintenance, for correct installation procedures.
• If the problem persists, call Service.
4
The image processing values sent by the host are invalid or in
conflict with one another.
• Check the job settings for illegal combinations. Refer to the
Scanning Setup Guide for valid values.
30
A document is lodged in the transport.
• Remove the documents that have been scanned from the
output tray.
• Open the pod.
• Remove any jammed documents from inside the transport.
• Close the pod.
NOTE: The following procedure is a general guideline. Your
procedure may be different depending on how your
application is set up.
• Verify the last document that was scanned correctly.
• Place any documents that were not scanned at the top of the
batch.
• Place the documents in the input elevator and begin scanning.
One or more documents that passed through the transport were
not scanned.
• Refeed all documents for which images were not obtained.
107
Calibration was attempted before the lamps were warmed up.
• Wait until the lamps have completely warmed (90 seconds)
and try the calibration again.
359, 19
Scanning was attempted before the lamps were warmed up.
• Wait for the message Lamps ready for scanning to be
displayed and scan again.
108
Informational message. The lamps are warmed and a calibration
can be performed now, if needed. This does not indicate that a
calibrate is needed.
280
Informational message. The lamps are warmed and scanning
can be initiated.
355
Informational message. The lamps were turned off due to
inactivity.
46
The scanner was started with an empty input elevator or the
portion of the document that is covering the paper present
sensor is too dark (the back side of the bottom page).
• Place the documents you want to scan in the input elevator
and try again.
• Offset the document until the paper present sensor detects it.