Change the pre-separation pad when the frequency of multi-fed
documents increases.
1. Open the pod.
2. Remove the pre-separation pad by lifting the pad up and out of
position.
3. Install the new pre-separation pad. Be sure it snaps into place.
4. Close the pod.
The imaging guides should be replaced when they are heavily
scratched and defects show in the image.
NOTE: Handle the imaging guides carefully so as to not put fingerprints
on the guides.
1. Open the pod.
2. Turn the screw on each end of the lower imaging guide to remove it
from its position.
3. Install the new imaging guide and turn the screws to secure the
imaging guide.
4. Repeat Steps 2 and 3 to replace the upper imaging guide.
5. Close the pod.