2. Indoor fan
<In cooling operation>
motor control
(This operation controls the fan speed at indoor unit side.)
The indoor fan (cross fl ow fan) is operated by the phase control
induction motor.
The fan rotates in 5 stages in MANUAL mode, and in 5 stages in
AUTO mode, respectively. (Table 1)
COOL ON
Fan speed setup
AUTO
(Fig. 2)
Ta
[ °C ]
+2.5
a
+2.0
b
+1.5
c
+1.0
d
+0.5
e
Tsc
*3 : Fan speed = (M + –L) × 3/4 + L
*4 : Fan speed = (M + –L) × 2/4 + L
*5 : Fan speed = (M + –L) × 1/4 + L
RAS-M10PKVP-E
Fan speed level
Fan speed Air flow rate
(rpm)
WF
1200
WE
UH
1200
WD
H
1140
WC
M+
1080
WB
1020
WA
M
960
W9
910
W8
L+
850
W7
L
790
W6
L–
770
W5
UL
700
W4
650
W3
SUL
600
W2
600
W1
520
Operation fl ow and applicable data, etc.
MANUAL
Indication
Fan speed
L
W7
L+
(L + M) / 2
M
WA
M+
(M + H) / 2
H
WD
Fan speed
Hi Power
M+(WC)
H (WD)
*3
*4
*5
L(W7)
L+(W8)
*6 : Fan speed = (H –L+) × 3/4 + L+
*7 : Fan speed = (H –L+) × 2/4 + L+
*8 : Fan speed = (H –L+) × 1/4 + L+
(Linear approximation from M+ and L)
(Table 1) Indoor fan air flow rate (Cooling, Dry)
RAS-M13PKVP-E
Fan speed Air flow rate
3
(m
/h)
(rpm)
690
1260
690
1260
640
1210
600
1130
560
1060
510
990
480
930
430
870
390
810
370
770
320
700
290
650
250
600
250
600
190
520
(Fig. 1)
Hi Power
W8
(L + M) / 2
WC
(M + H) / 2
WE
*6
*7
*8
RAS-M16PKVP-E
Fan speed Air flow rate
3
(m
/h)
(rpm)
730
1340
730
1340
690
1280
640
1200
590
1120
530
1040
490
980
450
930
400
880
370
770
320
700
290
650
250
600
250
600
190
520
– 31 –
Description
* Symbols
UH
: Ultra High
H
: High
M+
: Medium+
M
: Medium
L+
: Low+
L
: Low
L-
: Low–
UL
: Ultra Low
SUL
: Super Ultra Low
*
The fan speed broadly varies
due to position of the louver, etc.
The described value indicates
one under condition of inclining
downward blowing.
1) When setting the fan speed
to L, L+, M, M+ or H on the
remote controller, the operation
is performed with the constant
speed shown in Fig. 1.
2) When the fan speed mode is
manual and TA < 22°C and the
compressor stops, the fan speed
is controlled from W2 (20 seconds)
to 0 rpm (40 seconds).
3) When setting the fan speed to
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed
level shown in Fig. 2 and
Table 1 according to the setup
temperature, room temperature,
and heat exchanger temperature.
4) When the fan speed mode is
AUTO and the compressor
stops, the fan speed is
controlled from W2 (20 seconds)
to 0 rpm (40 seconds).
3
(m
/h)
790
790
750
690
630
570
530
490
450
370
320
290
250
250
190