9. Louver control
This function controls the air direction of the indoor unit.
1) Louver
•
The position is automatically controlled according to the operation mode (COOL/HEAT).
position
•
The set louver position is stored in memory by the microcomputer, and the louver returns to
the stored position when the next operation is performed. (Cooling/heating memory position)
The angle of the louver is indicated as the horizontal angle is 0°.
When the louver closes fully, it directs approx. 10° upward.
1) Louver position in cooling operation`
1 When the indoor humidity is high (Hu sensor valve)
2) Louver position in heating operation
3) Louver position in dry operation
2) Air direction
adjustment
•
3) Swing
1) When pushing [SWING] button during operation, the louver starts swinging.
2) Each time you push the SWING button, you can change the swing mode.
(Vertical swing → Horizontal swing → Vertical and Horizontal swing ® Stop swinging)
•
•
Operation fl ow and applicable data, etc.
C
o
l o
n i
g
o
p
r e
t a
o i
n
A /
U
Initial setting of "Cooling storage position"
Louver : Directs downward (23˚) 1
or more and the position of the louver is less than 29°, the louver moves to 29° to prevent the
air outlet from dew drop. And the louver can't move to less than 29°.
When the indoor humidity becomes low or the compressor speed becomes less than 23 rps,
the louver returns to the storage position.
H
e
t a
n i
g
o
p
r e
t a
o i
n
A /
U
Initial setting of "Heating storage position"
Louver : Directs downward (72˚)
In case that the following temperature is obtained
during 12 minutes or 12 to 25 minutes from start
of heating operation: Room temperature (TA)
< Set temperature (Tsc) –3.0
"Heating storage position"
Louver : Directs downward (72˚)
Horizontal
Inclined
blowing
blowing
The louver position can be arbitrarily set up by pushing [FIX] button.
Swing operation is performed in width 35° with the stop position as the centre.
If the stop position exceeds either upper or lower limit position, swing operation is performed in
width 35° from the limit which the stop position exceeded.
T
O
(
C
O
O
) L
"Cooling storage position"
Louver : Directs downward (34˚)
T
O
(
H
E
A
) T
"Heating storage position"
Louver : Directs downward (58˚)
SLEEP MODE operation
In case that the following temperature is obtained
during 12 to 25 minutes from start of heating
operation: Room temperature (TA)
Set temperature (Tsc) –3.0 or when 25 minutes
or more passed from start of heating operation.
"Cooling storage position"
Louver : Directs downward (23˚)
Initial setting of "Cooling storage position"
Initial setting of "Cooling storage position"
Louver : Directs downward (23˚)*1
Louver : Directs downward (23˚)*1
Inclined
Blowing
blowing
downward
– 38 –
Description
Louver angle
P
o
w
e
f r
l u
70%), the compressor speed is 23 rps
P
o
w
e
f r
l u
Dry operation
Dry operation
Inclined
Inclined
blowing
blowing
Horizontal
(0˚)