Download Print this page

Omron NS-CXDC1-V1 Brochure & Specs page 6

Programmable terminals
Hide thumbs Also See for NS-CXDC1-V1:

Advertisement

New functionality added in Ver. 6 extends
the ease of use of the NS-series PTs.
Smart Active Parts greatly reduce the number of drawing and programming steps.
Want to check an error or adjust
settings without any software
tools. But realization of Touch
Drastically reduce
screen and PLC program are
your programming
really time consuming.
Also, it is dangerous to use
and development
software tools since they can do
anything. Isn't it possible to
time.
show or set one only part of the
information?
See the error log of the PLC without
connecting software.
As an error
monitor
Only one single part is on the screen!
Refer to page 15 of this catalog to see the wide variety of Smart Active Parts.
Easy screen transfer from anywhere at higher speed.
High-speed screen
transfer through
Most computers now have an
USB port, and no serial
USB.
RS-232C ports are provided.
You may want to transfer
screens more easily at higher
speeds.
Note: Lot number 0325 or later is required
for USB screen transfer with NS-V1
models.
Screen transfers
It is very convenient to make
using Memory
backups without using a
computer. It is, however,
Cards are possible
troublesome to operate a DIP
from the
switch on the back of the PT
each time backups are required.
maintenance
You may want to make backups
menu.
periodically, but worry because
the DIP switch pins may break.
Even a single screen change in
a shipped machine involves a
risk, because a screen sent by
Screen transfer
e-mail needs to be transferred
to a person familiar with
through modems is
operation. Training workers to
understand operation is a hard
now possible.
job. Or service personnel need
to visit the site to change
screens.
10
PT System
Ver. 6 or Higher
Tool Functions Provided with Smart Active Parts
All you need to do is select the required Smart Active
Part in the CX-Designer and drag & drop it on the
screen see page 5).
Smart Active Parts not only reduce the number of
screen drawing and ladder programming steps, but
they also eliminate the need to debug.
Software functions are achieved on the screen
without software such as the CX- Programmer,
CX-Position, and DeviceNet Configurator.
Make PID settings for temperature
control without connecting software.
As a setting
device for
temperature
control
OMRON's
Temperature
Only three parts are on the screen!
Controller
(Direct Connection)
PT System
Ver. 6 or Higher
Data can be transferred over USB through a single
cable between the computer and PT. No devices for
serial RS-232C and USB conversion are required.
Moreover, USB allows high-speed screen transfer by
just connecting the cable.
Screen transfers
equivalent to
Ethernet.
Screen transfers using Memory Cards are possible
from the maintenance menu. No physical switch
operations are required on the rear panel.
Furthermore, easy operation is ensured with no wear
and tear of hardware, including the switch.
Memory
Card
Select from
Start downloading/
the system menu.
uploading.
The screens can be transferred from a computer in an
office through modems. The maintenance of
the screens is possible without touching the device.
Therefore, no training or engineer visits are required.
RS-232C
Modem
Modem
Improved Data Logging
Number of logging points greatly increased.
For example, the PT can log data at 2-second
intervals 24 hours a day (for a 43,200-point log).
The number of Always Log points has increased from 1,000 to 50,000
max. per line.
The total number of Always Log points increased from 5,000 to 50,000.
Example:
Logging 1 word and 1 address at 1-second intervals:
50,000 points, with 50,000 logging points per line.
Logging 1 word and 3 addresses at 1-second intervals:
50,000 points, with 16,666 logging points per line.
The number of logging points for one line depends on the number of
logging words and the number of logging addresses. For details, refer to
the manual.
Logging continues.
For example, you may want to log data at
2-second intervals 24 hours a day (a 302,400-point
log). This is possible with the NS Series.
When the logging data reaches the number of preset logging points,
the logging data can be automatically saved in a Memory Card in CSV
format. After automatic saving, the logging data will be cleared.
Therefore, it will be possible to continue logging. (The Memory Card
can hold a maximum of 1,000 files.)
Example:
Example: Logging 1 word and 1 address at 2-second intervals with
the number of logging points set to
43,200 (i.e., at 2-second intervals for 24 hours a day).
LOG001.CSV 04/06/04 10:00
Memory
It is possible to
Card
LOG002.CSV 04/06/05 10:00
make a one-week
Auto-
LOG003.CSV 04/06/06 10:00
log by
matically
LOG004.CSV 04/06/07 10:00
automatically
saved
LOG005.CSV 04/06/08 10:00
saving the data
LOG006.CSV 04/06/09 10:00
seven times.
LOG007.CSV 04/06/10 10:00
Logging data for each
Suffixes are automatically
day (43,200 points) is
added to file names set in
saved in the Memory
the CX-Designer.
Card in CSV format.
NS-V2 Hardware Means High Quality, High Performance, and High Capacity
High definition
Displays image data (BMP and JPG) beautifully.
NS-V2: 32,000 colors
NS5
4,096 colors
NS8
32,768 colors
NS10
32,768 colors
NS12
32,768 colors
Note: NS5-SQ0 (B)-V2: STN models have 4,096 colors.
NS5-TQ0 (B)-V2: TFT models have 32,768 colors.
Large-capacity image data
Three times the image data capacity for standard models
V 1
V 2
NS5
6 MB
20 MB
NS8/10/12-V1
NS8/10/12-V2
NS8
20 MB
60 MB
NS10
20 MB
60 MB
NS12
20 MB
60 MB
20 MB
60 MB
PT System
Ver. 6 or Higher
Past logs can be seen.
You may want to see logs saved in the past in a
Memory Card on the screen. This is possible with
the NS Series.
Log data in a Memory Card can be read on the screen with the read
file button. A list of files with time stamps will appear on the screen.
By selecting the desired file, the past log in the Memory Card can be
read.
The log data files in the Memory Card
appear as shown below when the read file
button is pressed.
Read file button
Standard data can be displayed in the data log.
You may want to save the present log data as
standard data in the Memory Card. This is
possible with the NS Series.
By pressing the save to file button, the displayed log data can be
saved in the Memory Card in CSV format. The saved log data can be
overlapped as standard data on the screen by pressing the read file
button. By turning the log start address ON and OFF, logged data can
be controlled to enable/disable logging.
Log start address
Standard data
Save to file button
Read file button
USB port compatibility with commercially available printers
Hard copies of screens can be printed out in color by USB-
compatible printers.
USB port included as
standard equipment
General printer compatible
Not
NS5
with USB port
Supported
USB cable
NS8
Supported
NS10
Supported
NS12
Supported
Manufacturer: EPSON or Canon
Recommended models
EPSON: PM-2200C, PM-930C, PM-870C,
EPSON and Canon
PM-740C, PM-900C, PM-D600,
printers supported.
PM-G720, PM-G730, PX-A650,
PM-G730, PM-D600, PX-A650
Canon: BJ-M70, BJ-M40, PIXUS550i, 50i, 80i,
IP2000, IP3100, IP4100, IP4100R, IP90
Faster drawing speed
High-speed screen switching
NS5
See note.
NS8
Yes
NS10
Yes
NS12
Yes
200-MHz RISC CPU
High-speed graphics controller
Note: The NS5
uses a different
graphic controller
from other models.
11

Advertisement

loading

This manual is also suitable for:

Ns8-v2Ns10-v2Ns12-v2Nsh5Ns5-v2