Connections through CPU Unit/Host Link
Model number
CPM1-10CDR/20CDR- /CPM1A-10CD/20CD/30CD/40CD -
CPM2A-30CD/40CD/60CD
-
CPM2C-10/20
-
CQM1-CPU21/CPU41-V1/CPU42-V1/CPU43-V1/CPU44-V1
CQM1H-CPU11/CPU21/CPU51/CPU61
C200HS-CPU21/CPU23/CPU31/CPU33
C200HE-CPU32(-Z)(See note.)/CPU42(-Z)
C200HG-CPU33(-Z)(See note.)/CPU43(-Z)/CPU53(-Z)(See note.)/CPU63(-Z)
C200HX-CPU34(-Z)(See note.)/CPU44(-Z)/CPU54(-Z)(See note.)/CPU64(-Z)/CPU65-Z/CPU85-Z
CS1G-CPU42(-V1)/CPU43(-V1)/CPU44(-V1)/CPU45(-V1)
CS1H-CPU63(-V1)/CPU64(-V1)/CPU65(-V1)/CPU66(-V1)/CPU67(-V1)
CV500-CPU01-V1/CV1000-CPU01-V1/CV2000-CPU01-V1/
CVM1-CPU01-V2/CPU11-V2/CPU21-V2
Note: The C200HW-COM02, C200HW-COM04, C200HW-COM05, or C200HW-COM06(-V1) Communications Board is required.

Standard Models

Model
Specifications
Model number Standards
Ethernet
Case color
name
Ivory
NS12-TS00-V2
No
Black
NS12-TS00B-V2
12-inch TFT
NS12
800 x 600 dots
Ivory
NS12-TS01-V2
Yes
Black
NS12-TS01B-V2
Ivory
NS10-TV00-V2
No
Black
NS10-TV00B-V2
10-inch TFT
NS10
640 x 480 dots
Ivory
NS10-TV01-V2
Yes
Black
NS10-TV01B-V2
Ivory
NS8-TV00-V2
No
Black
NS8-TV00B-V2
8-inch TFT
NS8
640 x 480 dots
Ivory
NS8-TV01-V2
Yes
Black
NS8-TV01B-V2
Ivory
NS5-SQ00-V2
No
Black
5-inch STN
NS5-SQ00B-V2
320 x 240 dots
Ivory
NS5-SQ01-V2
Yes
Black
NS5-SQ01B-V2
Ivory
NS5-TQ00-V2
No
Black
NS5-TQ00B-V2
5-inch TFT
NS5
320 x 240 dots
Ivory
NS5-TQ01-V2
Yes
Black
NS5-TQ01B-V2
Ivory
NS5-MQ00-V2
No
5-inch
Black
NS5-MQ00B-V2
monochrome
Ivory
NS5-MQ01-V2
320 x 240 dots
Yes
Black
NS5-MQ01B-V2
NS5
5-inch STN
No
Black
NSH5-SQR001B-V2
Hand-held
320 x 240 dots
22
Specifications
RS-232C or RS-422A adapter connected to peripheral port
RS-232C connector (9-pin)
Communications connectors include both a peripheral port and
RS-232C port (branching possible through CPM2C-CN111
Conversion Cable).
Used as separate peripheral and RS-232C ports through CS1W-
CN114/118 Conversion Cable.
RS-232C connector (9-pin)
RS-232C connector (9-pin) (Only peripheral port for CQM1H-CPU11)
RS-232C connector (9-pin, selectable)
RS-232C connector (9-pin)
RS-232C connector (9-pin, selectable)
Model name
Specifications
CU, CE
The CX-One is an integrated
tool package that provides
1 license
CU, CE
programming and monitoring
software for OMRON PLCs and
CU, CE
components. The CX-One runs
3 licenses
CU, CE
on any of the following
CX-One
operating systems:
CU, CE
FA Integrated
Windows 98 SE, Me, NT 4.0
10 licenses
Tool Package
(Service Pack 6a), 2000 (Service
CU, CE
Ver. 1.1
Pack 3 or higher), or XP.
CU, CE
CX-Designer version 1.
is
30 licenses
included in the CX-One.
CU, CE
Refer to the CX-One catalog
CU, CE
(R134) for details.
(See note 2.)
50 licenses
CU, CE
CU, CE
The CX-Designer can also be ordered individually using the following model number.
CU, CE
OS: Window 98 SE, Me, NT 4.0
(Service Pack 6a),
CU, CE
CX-Designer
2000 (Service Pack 3 or
1 license
CU, CE
Ver. 1.
higher), or XP.
The Ladder Monitor Software
CU, CE
is included.
CU, CE
Screen transfer cable for DOS/V
CU, CE
USB Host Cable, cable length: 5 m
CU, CE
Cable
USB Host Cable, cable length: 2 m
(See note 1.)
CU, CE
USB-RS-232C Conversion Cable,
CU, CE
cable length: 0.5 m
CU, CE
RS-422A cable (loose wires)
Cable length: 10 m
CU, CE
CU, CE
RS-232C cable (loose wires)
NSH5 Cables
Cable length: 3 m
CU, CE
RS-232C cable (loose wires)
CE,
Cable length: 10 m
CU
(approval
Length: 2 m
PT-to-PLC
PT connection: 9 pins
pending)
Connecting Cable
PLC connection: 9 pins
Length: 5 m
NSH5 Wall-mounting Bracket
Note 1: Use an OMRON USB Host Cable to connect an NS-series PT to a printer.
2: Site licenses are also available for users that need to use the CX-One on many computers.
Ask your OMRON representative for details.
Options
PLC model name
Model name
C Series: CPM1
C Series: CPM2A
Video Input
C Series: CPM2C
Unit
Special Cable for the Console
C Series: CQM1
C Series: CQM1H
Controller Link
Interface Unit
C Series: C200HS
C Series: C200HE (-Z)
C Series: C200HG (-Z)
C Series: C200HX (-Z)
CS Series: CS1G
RS-422A
CS Series: CS1H
Adapter
CVM1/CV Series:
CV500/1000/2000 or
CVM1
Anti-reflection Sheets
(5 surface sheets)
Protective Covers
Sheet/Cover
(5 pack)
Model number
(anti-reflection coating)
CXONE-AL01C-E
Protective Covers
(5 covers included)
(Transparent)
CXONE-AL03C-E
(NT625C/631/631C Series to NS12/10 Series)
CXONE-AL10C-E
(NT625C/631/631C Series to NS12/NS10 Series) (Black)
(NT610C Series to NS12/10 Series)
(NT620S/620C/600S Series to NS8 Series)
CXONE-AL30C-E
(NT600M/600G/610G/612G Series to NS8 Series)
CXONE-AL50C-E
Memory Card
Memory Card Adapter
Battery
Bar Code Reader
NS-CXDC1-V1
(Refer to the Catalog for details.)
Note: One screen cannot display two video inputs simultaneously.
XW2Z-S002
Related Products
NS-US52 (5 m)
NS-US22 (2 m)
WS02-NSFC1-EV2 Face Plate
CS1W-CIF31
Auto-Builder for NS
NSH5-422CW-10M
Significantly reduces the engineering time required by
NSH5-232CW-3M
combining LCB/LCU and the NS Series.
Automatic generation of control screens and tuning screens. Automatic
NSH5-232CW-10M
generation of NS screen data by the software from tag information created with
CX-Process Tool.
XW2Z-200T
NS communications address allocation, ladder programs, etc., are completely
XW2Z-500T
unnecessary.
NSH5-ATT02
Data that has been generated can be freely edited and processed by
CX-Designer (NS screen creation software).
NS Faceplate Auto-Builder upgraded to version 2.0.
Maximum number of automatically generated loops
increased from 32 to 100.
Automatic generation from the CX-Process projects
that use multiple nodes.
Automatic generation of detailed setting screens for
Line Segment programs.
Specifications
Product name
Face Plate Auto-Builder for NS
Specifications
Model number
Inputs: 4 channels
NS-CA001
Flush surface construction is used for superior
Signal type: NTSC/PAL
environmental resistance and the enclosure rating for
Input channels: 2 video
channels and 1 RGB
the front of the PT is IP65F compliant.
NS-CA002
channel (See note.)
IP International Protection
Signal mode: NTSC/PAL
6 Dust and dirt will not enter interior.
F150-VKP (2m)
F150-VKP (5m)
5
For Controller Link
NS-CLK21
Communications
Transmission distance:
500 m total length
F
Note: Use this model when
NS-AL002
connecting PT models without a V
suffix.
Note: PT models with a suffix of V
can also be connected.
Note: May not be applicable in environments with long-term exposure to water or oil.
Transmission distance:
50 m total length
Note: Only PT models with a suffix
CJ1W-CIF11
of V
are connectable. Use the
NS-002 to connect models without
a V
suffix.
The PTs conform to UL standards (cULus) and EC
NS12/10
NS12-KBA04
Directives.
NS8
NS7-KBA04
In addition, there are no export restrictions on the PTs.
NS5
NT30-KBA04
cULus certification is scheduled for the near future for
NS12/10
NS12-KBA05
the NSH5 5-inch Hand-held PT.
NS8
NS7-KBA05
NS5
NT31C-KBA05
NS12/10
NS12-KBA05N
NS8
NS7-KBA05N
NS5
NT31C-KBA05N
NS12-ATT01
NS12-ATT01B
NS12-ATT02
NS8-ATT01
NS8-ATT02
30 MB
HMC-EF372
64 MB
HMC-EF672
HMC-AP001
CJ1W-BAT01
V520-RH21-6
CX-Process Tool
(LCB/LCU programming software)
LCB/LCU program creation
(function block method)
CSV tag file output
Specifications
CSV tag files for LCB/LCU used in Face Plate Auto-Builder for NS
Superior environmental resistance
meets IP65F standards.
(Enclosure protects against foreign objects.)
There are no adverse effects from a water stream
from any direction.
(Enclosure protects against water intrusion.)
There are no harmful effects from oil droplets or
spray from any direction. (Enclosure protects
against oil intrusion.)
Meets International Standards and
Exports are Not Restricted
NS Series
Created screens are
easily transferred to the
NS by means of a
Memory Card or over
the network.
+
SYSMAC CS1
LCB/LCU
CX-Designer
(NS screen creation software)
CSV tag file for
NS project file
LCB/LCU
Editing created data
Creation of other required screens
Face Plate
Auto-Builder for NS
Model number
WS02-NSFC1-EV2
23

Advertisement

loading

This manual is also suitable for:

Ns8-v2Ns10-v2Ns12-v2Nsh5Ns5-v2