Remote Control Reset - Panasonic CS-W7DKE Service Manual

Table of Contents

Advertisement

CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE
− Release the generator complete wire (green and red).
(Fig. 8)
− Remove 2 screws on the right and 1 screw at the left
side of the control board. (Fig. 7)
− Press down the hook on the left side of control board.
(Fig. 7)
− Then pull out the Control Board Complete from the unit.
(Fig. 7)
− Remove the cross flow fan bushing from the chassis.
(Fig. 9)
− Loosen the fan boss screw at the cross flow fan. (Fig. 9)

12.4. Remote Control Reset

• When the batteries are inserted for the first time or the
batteries are replaced, you may notice the indications at
remote control's display screen blink continuously and not
functionable. If this condition happens, try to reset the
remote control by pushing the reset terminal with a pointing
device.
• You may also do the reset to erase the setting at remote
control and restore back the default setting.
Fig. 9
− Push up the evaporator and remove cross flow fan by
pulling both cross flow fan and fan motor. (Fig. 10)
68
Fig. 10