Panasonic CS-W7DKE Service Manual page 47

Table of Contents

Advertisement

Attached accessories
Applicable piping kit
CZ-3F5, 7BP (V7DK, V9DK, W7DK, W9DK)
CZ-4F5, 7, 10BP (V12DK, W12DK)
Select the best location
INDOOR UNIT
• There should not be any heat source or steam near
the unit.
• There should not be any obstacles blocking the air
circulation.
• A place where air circulation in the room is good.
• A place where drainage can be easily done.
• A place where noise prevention is taken into
consideration.
• Do not install the unit near the door way.
• Ensure the spaces indicated by arrows from the wall,
ceiling, fence or other obstacles.
• Recommended installation height for indoor unit
shall be at least 2.3 m.
OUTDOOR UNIT
• If an awning is built over the unit to prevent direct
sunlight or rain, be careful that heat radiation from
the condenser is not obstructed.
• There should not be any animal or plant which could
be affected by hot air discharged.
• Keep the spaces indicated by arrows from wall,
ceiling, fence or other obstacles.
• Do not place any obstacles which may cause a short
circuit of the discharged air.
• If piping length is over the rated length, additional
refrigerant should be added as shown in the table.
CS-W7DKE CU-W7DKE / CS-W9DKE CU-W9DKE / CS-W12DKE CU-W12DKE
Indoor/outdoor Unit Installation Diagram
• This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
47