Field setting mode
Others : Code 50✴✴
Main Menu &
Sub Menu Function
Code
Others Code
Outing
50✴✴
DHW Saving Mode
Power Peak Control
Outing Mode (Hot Key of Wired Remote Controller)
• All the target temperatures – space heating and cooling, water law, DHW, Room temperature – are set to the values
defined in the above table under the holiday mode (outing hot key)
• With the lowered target temperatures (FSV #5011 ~ #5019), the system operates normally.
NOTE
Economic DHW Heating
• DHW heating only by the heat pump to save energy. Target DHW temperature is lower than the temperature set by user.
The temperature difference is defined by FSV #5021. (default: 5°C)
- If user sets the temperature 45°C, the system sets the target temperature 40°C with the default setting.
Peak Power Control
• If users make contracts with local electric power company for limiting the amount of power consumption when a surge in
power usage, users can set FSV of "Forced off".
• According to FSV (#5041), Default is Non-usage. And According to FSV (#5042), If input is "0 (default)", Back up heater (BUH)
is unavailable while external contact is high.
If input is "1", Only Compressor (Heat Pump) is available.
If input is "2", Only Booster Heater (BSH) is available.
• Applying the control when power voltage of input contact is high is default. According to FSV (#5043), it is available to
adopt this logic in low condition exceptionally.
• When applying to this logic, SAMSUNG controller come to get "Thermo off" condition for all operation.
• If not used for a long time, anti-freeze fluid shall be used for preventing damage to the unit in cold condition.
Field Setting Value
Description
Water Out Temp for Cooling
Room Temp for Cooling
Water Out Temp for Heating
Room Temp for Heating
Auto Cooling WL1 Temp
Auto Cooling WL2 Temp
Auto Heating WL1 Temp
Auto Heating WL2 Temp
Target Tank Temp
Temp Difference
Application
Select forced off parts
Using input voltage
Frequency Ratio Control
ENGLISH-48
Sub Code
Default
Min
25
5
✴✴11
30
18
✴✴12
15
15
✴✴13
16
16
✴✴14
25
5
✴✴15
25
5
✴✴16
15
15
✴✴17
15
15
✴✴18
30
30
✴✴19
5
0
✴✴21
0(No)
0
✴✴41
0(All)
0
✴✴42
1(High) 0(Low)
✴✴43
0(No)
0
✴✴51
Max
Step Unit
25
1
˚C
30
1
˚C
55
1
˚C
30
1
˚C
25
1
˚C
25
1
˚C
55
1
˚C
55
1
˚C
70
1
˚C
40
1
˚C
1(Yes)
-
-
2
1
-
1
-
-
1(Yes)
-
-