Esp Control - Harman PC 45 Installation & Operating Manual

Corn/pellet stove
Table of Contents

Advertisement

Power Light
Indicates power to the
control.
Status Light
Will be lit in either stove
or room temp mode when
pointer is not within off
position band except
after normal shut down.
Blinks to indicate errors
listed  below.
Indicates power to
distribution blower.
 Indicates power to
combustion blower
Indicates power to the
feed motor.
Indicates igniter is on.
Temp dial
Allows you to adjust the room temperature in Room
Temp Mode using the outer scale marked in degrees
Fahrenheit. It also allows you to adjust the stove
temperature while in Stove Temp Mode using the inner
scale marked from 1 to 7.
Status  light  error  message
1 Blink: Indicates control board self diagnostic fail-
ure. This requires a manual reset*.
3 Blinks: Indicates ESP (Exhaust Sensing Probe)
failure. This requires a manual reset*.
4 Blinks: Can occur only in Room Temp Mode and
indicates Room Sensing Probe failed or not installed.
If a Room Sensing Probe is then installed, the sta-
tus light will automatically reset.
NOTE: Unit will not start in "AUTO" with this status
error.
5 Blinks (In Igniter Auto. Mode Only):  Indicates
that the unit has failed to light within the 45 minute
start cycle. To reset - Turn Mode Selector to "OFF",
then turn to either mode again.
AUTOMATIC IGNITION ESP CONTROL
Mode Selector
Allows you to choose between Room Temp
Mode, Stove Temp Mode, or OFF. Also allows
you to vary the distribution blower speed by
turning the knob to the high or low side of each
mode.
s:
6 Blinks : Indicates that the control has calculated
poor or incomplete combustion occurring for more
than  50  minutes.  See Troubleshooting  section  for
more details.
* Manual reset- Disconnect power cord for a few
seconds and reconnect. If error still occurs call your
Harman Dealer.
Feed adjuster
Sets the maximum
feed rate
Test
Runs all motors at full
speed for one minute
to  check  operation.
After two minutes the
stove  will  go  to
minimum  burn  and
the  blowers  will
alternate from high to
low every  minute to
remind you that you
are  still  in  "Test
Mode".
Igniter switch
Set to appropriate
Start-Up mode.
Distribution  Blower
speed adjustment range.
L = low
H = high
Variable speed anywhere
between  L  and  H;
although  as  the  stove
temp. goes up , so does
the L and H scale.
PC 45 Corn/Pellet Stove
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents